Ultrasounds
Moduson table
Ref :
223 008
The transmitter 2 is connected to the main transmitter. The main transmitter is powered via a
15 V power supply and its switches are set on Continuous and OFF, respectively (then its
transmitting member is cut off and only the transmitter 2 is powered).
The receiver is positioned in the circular recess closest to the transmitter (radius = 15 cm) in
which it can be moved. It is located in the right portion. It is connected by means of a
shielded cable to the vertical input of the oscilloscope.
 Material :
 Setup schematic
2.2 Step 2: Protocol
 Definitions
On the above schematic, the symbols have the following meanings:
 Measurements :
Different values are assigned to i by moving the transmitter in its guide and the position to be
given to the transmitter in order to obtain the direction of the radiation reflected on the mirror
is determined.
This direction is obtained by determining the receiver position on the arc of circle that yields
the highest amplitude for the received signal.
The oscilloscope settings are 0.1 V/div for vertical amplification and on 0.1 msec/div for
horizontal sweep.
To perform correct measurements, proceed as follows:
Note: The presence of other peaks (with lower amplitudes) is observed. This is due to
complex phenomena called « diffraction phenomena».
ENGLISH
-
MODUSON main ultrasonic transmitter and transmitter 2
-
One ultrasonic receiver
-
MODUSON moulded PVC table (two elements)
-
0–15V stabilised variable power supply
-
Oscilloscope
-
Banana-to-BNC adapter cable
F
Transmitter
On is the perpendicular to the mirror
i is the angle of incidence between the incident sound radiation EO and the
perpendicular to the mirror On
r is the angle of reflection between the reflected sound radiation OR and the
perpendicular to the mirror On
position the transmitter on the first value (10 degrees)
slowly move the receiver from the lowest value (towards 0 degree)
stop as soon as the first amplitude peak of the received signal is observed
read the corresponding value
fine-tune as required.
O
Mirror
r
i
R
n
44
Receiver

Publicité