Changing pellet loading (with self-regulation deactivated)
By pressing the "M" button on the remote control for two sec-
onds and scrolling the display with the "+" and "-" buttons, you
will come to the description "ADJ-PELLET (CAT)".
If automatic regulation is ON in the parameters, this setting of
manual ADJ is NOT possible.
When this is confi rmed the display reads "ADJ-PELLET ;
ADJ-DRAUGHT and RADIO MENU" (CAT). The pellet drop
can be adjusted manually by changing the capacity in percenta-
ge terms (+/- 30 %).
By confi rming this function with the menu key, you can access
the function to adjust pellet loading. By decreasing the
value set, pellet loading is decreased. By increasing the value
set, pellet loading increases. This function is useful if
changing the pellet type for which the stove has been calibrated
and loading therefore needs correcting.
Should this correction not suffi ce, contact the Edilkamin-autho-
rised Dealer, to establish the new operating axis.
Notes on fl ame variability
Flame status may vary depending on the type of pellet used,
in addition to normal solid fuel fl ame variability and regular
combustion chamber cleaning carried out automatically by the
boiler.
(N.B.: which does NOT replace necessary cold suction by the
user prior to ignition).
RESERVE WARNING
The stove is fi tted with an electronic function that detects the
residual quantity of pellets in the tank.
The detection system is integrated into the electronic board,
allowing you to see how many hours and kg are left until
pellet exhaustion, at all times. For correct system function, it is
important that the following procedure is followed during the
fi rst ignition (by the Dealer).
This provides a reference indicator. Greater precision is
obtained by regularly zeroing the system before fi lling it again.
Edilkamin does not accept any responsibility for differences
from what is indicated (which may be due to external factors).
Pellet reserve system
Before enabling the system, you need to load a sack of pellets
into the tank and use the stove until the loaded
fuel has run out. This allows for a short system road test.
After this, the tank can be fi lled completely and the stove
started up.
When running, at the time at which a whole 15 kg sack of pel-
lets can be loaded, the display will show the word
"Reserve" fl ashing.
At this point, after having poured in a sack of pellets, you need
to 'inform' the memory that you have loaded 15 kg.
To do so, proceed as follows:
1. press the "M" key (for approximately 3-4 seconds) until the
word "Clock" appears.
2. press the "+" key until the word "Reserve pellet" appears.
3. press the "M" key until the following screen appears,
INSTRUCTIONS FOR USE
- 42
Kg remaining in tank
then use the "+" key to take the fi gure (*) to the value equal to
the Kg of pellets loaded (15 kg in the above example).
4. press the "M" key to confi rm
5. press the key
to exit.
After having completed the above procedure, after having con-
sumed the 15 kg, the wording "Reserve" will appear
fl ashing at intervals. After which the operation must be repea-
ted, from point 1 to point 5.
SIMPLIFIED LIGHTING BUTTON
If the remote control device does not work, you can carry out
the basic functions by means of a red emergency button placed
on the back of the stove (see Fig. 1).
Push this button once or more times to activate the required
function:
1. STOVE OFF
by pressing the red button for 2 seconds this turns on.
1 beep confi rms the command
2. STOVE ON
by pressing the red button for 2 seconds this turns off.
1 beep confi rms the command
3. WITH STOVE IN STAND-BY MODE
pressing the red button for 5 seconds, the stove lights with
wood using the pellets (LIGHT WOOD function) 3 beeps con-
fi rm the command.
fi g. 1
-