Les langues disponibles

Water Inlet
Nut
Drain Valve
Disconnect drain valve power.
Disconnect level sensing wires.
Disconnect limit switch wires.
Disconnect door power.
7. Disconnect the Components
Installations Requiring Disassembly Only
Disassembly Checkpoint #3
The steps below may not be necessary. Make sure removing the bath from the frame is
required. The bath likely can be moved into place while attached to the frame.
If the bath can be moved into place without performing these steps, go directly to
"Position the Bath."
IMPORTANT! Save and organize all screws and hardware. All parts will be reused.
Disconnect the water inlet from the drain valve by loosening the nut. Save the O-ring.
Disconnect the level sensing wires at the controller.
Disconnect the limit switch wires at the controller and pulley assembly.
Disconnect the door power wire at the controller.
Disconnect the Bath from the Frame
IMPORTANT! Be careful not to strip or damage the screws when removing them. When the bath is
reattached they will be reused, as will the original holes in each of the wood blocks.
Disassemble the bath from the support frame at each of the four brackets by removing the two
screws.
Carefully lift the bath clear of the frame and set it aside.
Temporarily secure any loose wires and protect them from being damaged.
Kohler Co.
Power Cord
Open
J1
J2
J3
J4
J5
J6
and
J7
15
Bracket
Wood Block
Remove all screws
from (4) brackets.
Controller
1128532-2-C

Publicité