Making Measurements
– Your multimeter can display diode forward-bias of up to approximately 3.1 V.
NOTE
– If the beeper is enabled during diode test, the multimeter will beep briefly for
Reverse the probes (as shown in
diode again. Assess the diode according to the following guidelines:
Figure 2-21
80
The forward-bias of a typical diode is within the range of 0.3 V to 0.8 V;
however, the reading can vary depending on the resistance of other
pathways between the probe tips.
a normal junction and sound continuously for a shorted junction, below
0.050 V. See
"Changing the beep frequency"
beeper.
– A diode is considered good if the multimeter displays OL in reverse-bias
mode.
– A diode is considered shorted if the multimeter displays approximately 0 V
in both forward- and reverse-bias modes, and the multimeter beeps
continuously.
– A diode is considered open if the multimeter displays OL in both forward-
and reverse-bias modes.
Open diode display
on page 138 to disable the
Figure
2-23) and measure the voltage across the