Les langues disponibles

Slowdown AST control
Adjust the obstruction detection sensitivity during slowdown in percentage terms.
The parameter is only used if the opening or closing slowdown point is active.
Confi guration>
Gate travel settings
Impact test
Activate/deactivate test mode for impact tests. With the function on, the operator does not signal errors connected to obstacle
detection after more than one consecutive impact.
Test mode is deactivated automatically after 1 hour.
With the function on, the display shows the
Confi guration>
Gate travel settings
Confi gure travel M1
Modify certain parameters previously described for motor M1 only (where diff erent from M2).
The function appears only with M1+M2 selected in [Function Number of Motors].
Confi guration>
Gate travel settings>
Confi gure travel M1
Slowdown AST control
icon.
Impact test
Opening speed
Closing speed
Opening approach space
Closing approach space
Opening slowdown point
Closing slowdown point
Opening slowdown speed
Closing slowdown speed
Deactivated (Default)
Maximum thrust and low obstruction sensitivity.
Minimum
Average
Maximum*
(*) Minimum thrust and high obstruction sensitivity.
Customised
Customised closing
Customised opening
The personalised values to be used are expressed as a
percentage:
- from 10% (minimum thrust and high obstruction
sensitivity)
- to 100% (maximum thrust and low obstruction sensitivity)
Activate test mode
Deactivate test mode
See the specifi c parameters for each function.