Devices with BUS CXN system
The CXN CAME system is a two-wire non-polarised communication BUS which allows you to connect up all compatible CAME
devices.
Connection to the BUS can be in a chain, star or mixed formation.
Once the system has been wired, and after having set the address on each device, the function of each accessory can be
confi gured on the control panel. This method allows you to confi gure the set-up immediately without having to do so later and
intervene directly on the accessories and system wiring.
The CXN BUS can support control devices, photocells, safety devices, beacons and gateways at the same time.
Cabling
1
Chain connection
2
Star connection
3
Mixed connection
Cable type
We recommend using a FROR 2x1mm² cable, maximum length from the control board: 50 m.
Single branch length (m)
BUS cable
The total length of all branches can be a maximum of 150 m.
The cable cannot be shielded.
Maximum number of devices that can be connected, by type
Type of device
Selectors
Photocell pairs
Flashing beacons
max. 50 m
2 x 1 mm²
Maximum number of devices per type
7
8
2