CAME ZLX24SA Mode D'emploi page 70

Masquer les pouces Voir aussi pour ZLX24SA:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2
Power supply output for accessories
The output normally delivers 26 V AC.
The output delivers 24 V DC (10+, 11-) when the batteries start operating, if they are installed.
3
Connection to one or two electric locks 12 V AC/DC - max 15 W
Maximum capacity of contacts
The total power of the outputs listed below must not exceed the maximum output power [Accessories]
Device
Accessories
Additional light
Flashing beacon
Operator status warning light
The outputs deliver 24 V DC when the batteries start operating, if they are installed.
Device
Auxiliary contact
BUS CXN
Do not connect anything other than CAME BUS accessories.
10 11 E E3 5
R1
M1 N1 ENC1 EB1+VB
Output
Power supply (V)
10 - 11
26 AC
10 - E3
26 AC
10 - E
26 AC
10 - 5
26 AC
Output
Power supply (V)
B1 - B2
BUS
15 DC
R2
M2 N2 ENC2 EB2+VB
Maximum power
(W)
20
10
10
3
Power (W)
-
24 (24V AC/DC)
15

Publicité