Limit-switch function
Set the operation of the inputs for slowdown/end-of-travel switches.
The function only appears for motors confi gured for this purpose.
If the value set for M1 is diff erent to the value set for M2, only the value for M2 is shown here.
After modifying the function of the slowdown/end-of-travel inputs, recalibrate [Function Travel calibration].
If the inputs are used for slowdown, once calibration is complete, the board automatically sets the slowdown
points. These parameters can, however, be modifi ed. They allow for slowdown even if the slowdown switch is not
seen.
The type of input (N.O. or N.C.) can be modifi ed only with the generic motor [Function Type of limit switch]. In all
other cases, use the type envisaged by the specifi c motor.
Confi guration>
Motor settings
Input type FC/FA
Set the inputs type FC/FA.
The function appears only with generic motors [Function Motor Type set to Generic].
Confi guration>
Motor settings
Motor test
Check the gate leaves open in the right direction.
With the function active, the > key opens the gate leaf connected to M2, and the < key opens the gate leaf connected to M1.
The movement continues while the key is pressed or until the end-of-travel limit switch is reached. When the key is released,
the movement stops.
If the leaf does not move in the correct direction, invert the motor phases.
The leaves will move at reduced speed.
Confi guration>
Motor settings
Travel calibration
Start the travel self-learning.
Confi guration>
Motor settings
Motor power
Setting power range of motors connected on M1 and M2.
The parameter is used only with generic motors [Function Motor Type set to Generic].
Confi guration>
Motor settings
Limit-switch function
Input type FC/FA
Motor test
Travel calibration
Motor power
Off
Stop in FA, stop in FC
Slowdown in FA/FC (Default)
Stop in FA, slowdown in FC
N.O. (Default)
N.C.
N.C. for FA input, N.O. for FC input
The > button opens gate leaf M2
The < button opens gate leaf M1
Minimum power [up to 120W]
Medium power (Default) [up to 200W]
Maximum power [more than 200W]