CAME ZLX24SA Mode D'emploi page 92

Masquer les pouces Voir aussi pour ZLX24SA:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Opening slowdown point
Set the percentage of the total travel to be used for the M1 and M2 opening slowdown.
If the value set for M1 is diff erent to the value set for M2, only the value for M2 is shown here.
Confi guration>
Gate travel settings
Closing slowdown point
Set the percentage of the total travel to be used for the M1 and M2 closing slowdown.
If the value set for M1 is diff erent to the value set for M2, only the value for M2 is shown here.
Confi guration>
Gate travel settings
Opening slowdown speed
Set the M1 and M2 slowdown speed during opening (as a percentage of the maximum speed).
If the value set for M1 is diff erent to the value set for M2, only the value for M2 is shown here.
The parameter is only used with the [Opening slowdown point] function active.
For Stylo ME and Stylo RME motors it might be necessary to reduce the minimum voltage applicable to the
motor to achieve the desired slowdown percentage. See function [Reduction of speed].
Confi guration>
Gate travel settings
Closing slowdown speed
Set the M1 and M2 slowdown speed during closing (as a percentage of the maximum speed).
If the value set for M1 is diff erent to the value set for M2, only the value for M2 is shown here.
The parameter is only used with the [Closing slowdown point] function active.
For Stylo ME and Stylo RME motors it might be necessary to reduce the minimum voltage applicable to the
motor to achieve the desired slowdown percentage. See function [Reduction of speed].
Confi guration>
Gate travel settings
Opening slowdown point
Closing slowdown point
Opening slowdown speed
Closing slowdown speed
Deactivated (Default)
1% to 50%
Closing slowdown point
10% to 50% (Default 40%)
10% to 50% (Default 40%)

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Zlx24sr

Table des Matières