19. Reinstall the driver cover, ensuring no wires are being pinched between
the driver cover and the luminaire housing.
20. Re-install the ten (10) socket head cap screws and lock washers from the
driver cover using a 5mm hex wrench or bit.
21. Replace any damaged or missing cover screws. Use only alloy steel M6-
1.5 x 20mm screws.
22. Tighten cover screws in a criss-cross pattern and torque to 45 in.-lbs.
23. Reconnect the conduit or fittings to the driver cover entries.
24. Reconnect input wires per wiring diagrams.
25. Re-install threaded access cap (see "Wiring the Lighting Fixture").
Driver replacement instructions for UNV34 fixtures
2.
Be sure to de-energize the luminaire before performing any maintenance.
3.
Driver replacement requires removal of the driver cover (see Figure 13).
4.
Open the threaded wiring access cap (see Figure 8) and allow the cap to
hang by the lanyard.
5.
Disconnect the input wires (line in, neutral and ground).
6.
Disconnect the conduit or fittings from the driver cover entries.
7 .
Remove the ten (10) socket head cap screws and lock washers from the
driver cover using a 5mm hex wrench or bit.
8.
Ensure all driver cover screws have been removed.
9.
Remove the driver cover.
10. Disconnect the input and output leads of the old driver (see Figure 13).
11.
Remove the two (2) screws that secure the driver; remove the old driver.
12. Replace with new driver supplied by Eaton's Crouse-Hinds.
13. Reconnect output wires per wiring diagram. Ensure that the positive (+)
and negative (-) leads of the drivers are connected per the wiring diagram.
14. Re-install the new driver into the luminaire, ensuring that the driver is in
direct contact with the luminaire housing and no wires are being pinched
between the driver and the housing. Secure with two (2) screws and
tighten to 5 in.-lbs. (0.6 N-m).
15. Ensure that output wires to LED boards are tied neatly next to the driver
and the input and dimming wire leads are tied neatly together (see Figure
13).
16. Reinstall the driver cover, ensuring no wires are being pinched between
the driver cover and the luminaire housing.
17 .
Re-install the ten (10) socket head cap screws and lock washers from the
driver cover using a 5mm hex wrench or bit.
18. Replace any damaged or missing cover screws. Use only alloy steel M6-
1.5 x 20mm screws.
19. Tighten cover screws in a criss-cross pattern and torque to 45 in.-lbs.
20. Reconnect the conduit or fittings to the driver cover entries.
21. Reconnect input wires per wiring diagrams.
22. Re-install threaded access cap (see "Wiring the Lighting Fixture").
Figure 12
All statements, technical information and recommendations contained herein are based on information and tests we believe to be reliable. The accuracy or completeness thereof are not
guaranteed. In accordance with Eaton's Crouse-Hinds Division's "Terms and Conditions of Sale," and since conditions of use are outside our control, the purchaser should determine
the suitability of the product for his intended use and assumes all risk and liability whatsoever in connection therewith.
Figure 13A
Figure 13B
Eaton's Crouse-Hinds Division
1201 Wolf Street Syracuse, NY 13208 • U.S.A.
Copyright© 2021
PAINT SHIELD INSTALLATION INSTRUCTIONS
ZPL PS2 and ZPL PS4 accessories are paint shields that can be installed by the
customer over the lens of the ZPLA to minimize paint overspray accumulation
on the light emitting surface.
1.
Ensure all previous installation steps have been followed.
2.
Locate the shield over the light emitting surface with the open portion
facing the luminaire (see Figure 14).
3.
Hook one side of the shield over the flange on one side of the luminaire
housing.
4.
Push on the opposite side of the paint shield to snap it over the flange on
the luminaire housing.
Paint Shield

REPLACEMENT PARTS

Eaton's Crouse-Hinds series linear LED fixtures are designed to provide years
of reliable lighting performance. However, should the need for replacement
parts arise, they are available through your authorized Eaton's Crouse-Hinds
distributor. Assistance may also be obtained through your local Eaton's Crouse-
Hinds representative or the Eaton's Crouse-Hinds Sales Service Department,
1201 Wolf Street, Syracuse, New York 13208, Phone 866-764-5454.
Figure 14