Eaton CROUSE-HINDS Pauluhn ZPLA Serie Manuel D'instructions page 4

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2 Foot
2 Foot
4 Foot
Length
(in)
(mm)
(in)
27 .0
685
44.6
A
18-
12-24
305-610
B
41.6
200.4
164.4
7.22 - 7.89
6.47
165.1
6.50
A
B
Figure 6. PM KIT – Pole Mount Installation
Dimension (inches)
8
7
Configuration
NOTES:
A
B
C
1. PLACE PARTS IN BAG AND LABEL
PM Kit 2.0 (trade
4.331
3.543
2.36
size 2")
PM Kit 1.5 (trade
3.740
2.953
2.00
size 1 - 1/2")
DIMENSION (INCHES)
CONFIGURATION
PM Kit 1.25 (trade
3.386
2.598
1.65
A
B
C [mm]
size 1 - 1/14")
DIAMETER 60
4.331
3.543
2.36
60
DIAMETER 51
3.740
2.953
2.01
51
DIAMETER 42
3.386
2.598
1.65
42
5/16 Screw
Clamp
Side
Channel
1/4 Set Screw
Figure 7. PM KIT – Pole Mount Details
SECONDARY SUPPORT
If using secondary support, attach one end of the support cable to a corner
eyelet provided on the fixture housing and secure the other end to a fixed
support. Use a minimum of two (2) support cables per fixture, securing at least
one to each end of the fixture housing.
8
7
WIRING THE LIGHTING FIXTURE
!
To maintain explosion proof integrity, make sure all threads are fully engaged.
1.
Open the threaded wiring access cap (see Figure 8) and allow the cap to
hang by the lanyard. All components in the fixture are pre-wired so only
input power needs to be connected in the fixture to the lead wires (or
terminals) per the wiring diagrams (see Figures 10 and 11) using methods
that comply with all applicable codes. Terminate the equipment grounding
conductor (green) first, the common (white) next, and finally, the line
voltage (black) last. For DC voltage applications, connect the positive (+)
lead to the white wire and the negative (-) lead to the black wire. Tighten
all electrical connections. Note - Standard openings are 3/4" NPT.
2.
If employing the dimming function of the drivers: Use only listed 0-10
VDC lighting controls. Ensure controls are rated for the hazardous
location in which they are being installed. Follow manufacturer's
installation instructions and applicable wiring methods as required by
NEC/CEC. Ensure the power to the lighting control and the LED fixture
are disconnected. Using wire rated for minimum of 75°C for ambient
temperatures not exceeding 55°C, or wire rated for a minimum of 90°C
for ambient temperatures not exceeding 65°C, connect the positive
terminal from the lighting control unit to the purple (+) lead wire of the
IF 1910 • 03/21
4 Foot
(mm)
1133
610-1056
A
B
6
5
D
1.693
1.535
A
B
1.378
D
1.693
1.535
1.378
Ø C
D
6
5
WARNING
Copyright © 2021, Eaton's Crouse-Hinds Division
driver, then connect the negative terminal of the lighting control unit to the
gray (-) lead wire of the LED driver.
3.
Re-install the threaded access cap. Ensure gasket is seated and clean
of debris. (CAUTION: When replacing cap, make sure that there are no
protruding wire connectors which can be pinched in between the driver
and cap).
4.
For loop feed wiring, use both entries to daisy chain multiple fixtures
(maximum of nine (9)). Refer to schematic for wiring. Only three (3)
conductors maximum are allowed through each entry hub. NOTE: Loop
feed is not available with the -SRG suffix (surge protector option).
Driver Cover
Access Cap
WIRING INSTALLATION CHECKLIST
3
4
1.
Verify sufficient HTL Lubricant is on conduit entries (recommend
approximately 1/8" bead around the first thread) and that all unused
conduit entries on the driver cover are closed with lubricated plugs (see
Figure 9).
2.
Verify conduit is installed for at least five (5) full threads into the driver
cover conduit entries.
3.
Verify installed conduit plugs are torqued to 42-52 ft.-lbs. (57-71 N-m) for
3/4" plug.
4.
Verify supply wires are connected to luminaire wire leads per figure 10 for
UNV1 fixtures and figure 11 for UNV34 fixtures.
5.
Verify all electrical connections are tightened.
6.
Verify all wires are safely and neatly inside access
cap and not on top of driver. Re-attach access cap
to fixture housing.
7 .
Verify access cap is tight and cap is in contact with
fixture housing.
CLAMP SIZE
(mm)
9
10C01-025D20
8
11A12-025D
7
10K01-031D
6
11A12-031D
5
10C01-031D32
4
10C01-031D20
3
0306682-2
2
0903016
1
0903015
ITEM
DWG NUMBER
NO.
DIR NUMBER:
1020306691///
TOLERANCES
UNLESS OTHERWISE SPECIFIED, ALL
THIS IS PROPERTY OF EATON AND CONTAINS CONFIDENTIAL
UNLESS OTHERWISE SPECIFIED
AND TRADE SECRET INFORMATION. POSSESSION DOES NOT
mm
INCHES. DIMENSIONS IN [ ] ARE IN
CONVEY ANY RIGHTS TO LOAN, SELL OR DISCLOSE SAID
in.
±
± .3
INFORMATION. REPRODUCTION OR USE FOR ANY PURPOSE
.X
OTHER THAN WHICH IT WAS SUPPLIED MAY NOT BE MADE
.XX
± .01
±
.13
ORIGINAL DATE
WITHOUT EXPRESS WRITTEN PERMISSION OF EATON.
.XXX
± .005
±
THIS DRAWING IS ON LOAN AND IS TO BE
ANGLES
±
1.5 °
±
1.5 °
RETURNED UPON REQUEST.
MATERIAL:
REDRAWN DATE
DRAWN BY
FINISH:
CHECKED BY
APPROVED BY
NEXT ASSY.
USED ON
HEAT TREATMENT:
APPROVED BY
THIRD ANGLE PROJECTION
APPLICATION
PATT. I.B.
4
3
Figure 8
2
1
D
C
CLAMP,
CLAMP,
MATERIAL
UPPER PART
LOWER PART
NO.
NO.
SS - 316
CHR5227
CHR5236
42
SS - 304
CHR5228
CHR5237
STL, ZNC PLTNG
CHR5229
CHR5238
SS - 316
CHR5230
CHR5239
51
SS - 304
CHR5231
CHR5240
STL, ZNC PLTNG
CHR5232
CHR5241
B
SS - 316
CHR5233
CHR5242
60
SS - 304
CHR5234
CHR5243
STL, ZNC PLTNG
CHR5235
CHR5244
2
SCREW, HEX HD, 1/20 x 5/8"
2
WASHER, LOCK, SPRING, 1/4"
NUT, HEX, 5/16-18
3
3
WASHER, LOCK, SPRING, 5/16"
2
SCREW, HEX HD, 5/16-18 x 1"
SCREW, HEX HD, 5/16-18 x 5/8"
1
DURA PRO BACK MOUNT
1
PIPE CLAMP, UPPER
1
PIPE CLAMP, LOWER
1
DESCRIPTION
QTY
A
PRIMARY DIMENSIONS ARE IN
MILLIMETERS.
PIPE MOUNT KIT, S/A
TITLE
07/02/2014
(PMKIT)
T. DALY
FIRST MADE FOR
MLL
DRT
SIZE
CODE IDENT. NO.
0306691
REV.
D
X1
PSB
SCALE 2:1
IB
WT. 0.50 LB
SHEET 1 OF 2
2
1
Figure 9
Page 4