Fig. 2.22
Unscrew the combustion air nozzles
4
Fig. 2.23
Install the lower back wall and panel supplied
We reserve the right to make technical changes
4
Fig. 2.24
Install the lower back wall and panel supplied
● Route the cable such that the cables are not touching any hot
stove surfaces!
● Take care to ensure that no cables are lying next to the motor
slewing ring after installation of the combustion air damper and
no cables can be damaged as a result!
● Activate the combustion air damper and check it is functioning
properly!
● Install the panel and lower back wall again.
● If the combustion air damper is screwed onto the bottom, close
the hole in the bottom of the rear wall with the cover and screws
(enclosed with the pellet fireplace)!
4