Olsberg INARA 2.0 Mode D'emploi Pour L'utilisateur page 88

Poêle à granulés
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operating manual
GB
for the user
Warnings
The ongoing combustion process is halted while there is a warning.
As long as the pellet fireplace is in
the combustion process, the warning is constantly visible. If a warn-
ing occurs while in standby, then the combustion process is not
permitted to start.
The warning is visible for 5 seconds every 30 seconds.
Display notification
Ext. requirement blocked
Outside the switching times
Flame temperature too warm
Room temperature too warm
Pellet cover open
Boiler temperature too warm
88
| 154
Cause of the fault
ū Connector not plugged in.
ū External room thermostat is not connected or is in-
correctly connected.
ū The temperature which has been set on the exter-
nal room thermostat is lower than the current room
temperature.
ū Active switching times are saved, and the current
time is outside the active switching times.
ū In "Automatic" operating mode, no night time reduc-
tion temperature is saved either.
ū The flame temperature is too high.
ū The current room temperature is too high (in
"Automatic" operating mode only).
ū Pellet reservoir cover open!
ū The water temperature in the pellet fireplace is too
high.
Possible remedy
● Plug the connector in!
● Connect the external room thermostat!
● Wait until the current room temperature has cooled
and the pellet fireplace starts automatically!
● Increase the desired temperature on the room
thermostat!
● Wait until the current time is within the active
switching times and the pellet fireplace starts
automatically!
● Define new switching times. Define a night time
reduction!
● Pellet fireplace can be started with the party
button.
● Wait until the flame temperature has cooled and
the pellet fireplace starts automatically!
● Wait until the current room temperature has cooled
and the pellet fireplace starts automatically!
● Increase the desired room temperature!
● Close the pellet reservoir cover!
● Wait until the current water temperature has cooled
and the pellet fireplace starts automatically!
We reserve the right to make technical changes
LEVANA 2.0 6 kW
LEVANA 2.0 8 kW
LEVANA AQUA 2.0
ARINA 2.0
INARA 2.0

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Levana 2.0Levana aqua 2.0Arina 2.0

Table des Matières