English
30
CLEAN
DESCALING
BREW GROUP CLEAN
QUICK MILK CLEAN
DEEP MILK CLEAN
4219-465-02851 MAN. GAG. MAGENTA Milk 120V EN-FR Rev 01.indd 30
Descaling
Descaling procedure
Descaling needs to be carried out when the machine requires it.
Use only Gaggia descaling solution designed to guarantee the machine's excellent
performance. The use of different products could damage the machine and leave
residue in the water. Failure to descale the machine will void the warranty.
1
Remove the Capp in Cup system if fitted on the machine.
2
Press CLEAN/SET
display.
clean/setting
Select " DESCALING " and after confirming with "
-
button to start.
START/STOP
3
Remove the drip tray and the coffee pucks container, empty and place them all
back into the machine.
4
Remove the water tank and empty it. Remove the INTENZA+ filter, if in place.
5
Pour the entire bottle of Gaggia descaling solution into the water tank and fill
the tank with water up to the CALC CLEAN level. Reinsert it into the machine.
6
Place a large recipient (1.5l) under the steam tube and the coffee dispensing
spout.
7
Follow the instructions shown on the display to launch the descaling
procedure. This procedure lasts approximately 25 minutes and consists of
a descaling cycle and a rinse cycle, carried out with dispensing at regular
intervals.
8
Once the descaling cycle is complete, rinse the water circuit and tank by
following the instructions shown on the display.
9
Position the INTENZA+ filter back into the water tank.
Note: it is possible to pause and resume the procedure at any time by pressing the
START/STOP
button.
START/STOP
Warning: when the descaling procedure is active, the brew group cannot be
removed. Wait for the descaling process to end, then remove the brew group.
button and select the "CLEAN " button shown on the
" press the START/STOP
21/01/2021 12:05:44