Setting The Scsi Id; Setting The Terminator - Sony UP-D6500 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Setting the SCSI ID

Up to seven SCSI devices can be connected to the
SCSI bus by daisy chaining. Each SCSI device is
recognized by its ID number, from 0 to 7.
Turn off the power to the printer, and set the printer ID
number with the SCSI ID switches on the rear, so that
it is unique from any other SCSI device. When shipped
from the factory, the SCSI ID is set to "2".
The SCSI ID number is set by the combination of three
SCSI ID switch settings.
The SCSI ID consists of the sum of the ID
number of each switch that is turned on.
ON
1
OFF
ID=0 ID=1 ID=2 ID=3 ID=4 ID=5 ID=6 ID=7
Switch 4 OFF ON
OFF ON
Switch 3 OFF OFF ON
Switch 2 OFF OFF OFF OFF ON
Note
When setting the SCSI ID, be careful not to duplicate
the number of another device on the SCSI bus. The ID
must be unique for each device.
TERMINATOR
SCSI ID
4
2
1
Switch 4
2
3
4
0
0
0
Switch 3
Switch 2
OFF ON
OFF ON
ON
OFF OFF ON
ON
ON
ON
ON

Setting the Terminator

The leftmost switch of the SCSI ID switches is the
terminator switch. Turning this switch on enables the
internal SCSI terminator.
If either of the SCSI connectors is not used in the
installation, turn the terminator switch ON.
19