Controls And Signals; How To Start The Production Of Slush, Sherbets Or Cold Drinks - ELMECO BIG BIZ Manuel Pour L'emploi Et L'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Control and signals
: product density
indicator leds (min 1 max 3);
: product cooling activity
indicator;
: "slush" mode functioning
indicator;
: "cold drink" mode
functioning indicator;
: machine switch button;
: mode selection button
Self diagnostics
If the LED blinks on the
electronic board with the
value 1, 2 or with the slush
and cold drink value, see the
tables at the end of this
guide, the Web site "Problem
Solving" of www.elmeco.com,
or call the service centre.
Configuration memory
All the functioning modes and
the regulations set are
registered in a non-volatile
memory which is active even
without power; therefore,
when you switch on the
machine, the tank keeps the
configuration it had when you
switched it off.
How to start the
production of slush,
sherbets or cold
drinks
The maximum amount of
liquid that the tank can hold is
(granita 5.5 / 6lt - creams
3/4lt).
If you switch on Big Biz and
only the augers start moving
while the cooling system is
not working yet.
 Clean the machine as
previously described.
 Remove the cover and put
the mix in the tanks.
Warning: the temperature
of the poured product must
not be lower than 5 °C in
order to allow a correct
calibration of the electronic
board, this will be indicate
with blink of led 3.
 Switch on the main switch
(see picture 7 pag.36).
- 15 -
 Switch on the auger switch
;
 by pressing the mode
selection button
can change from freezing
off to "1 slush" value, that's
to say from the lowest
product density level. If the
product temperature is
higher than 5 °C, automati-
cally, will start the calibra-
tion procedure and the led
3 will blink. The blinking of
led 3 will stop when the
calibration procedure will
be finished (about 2
minutes), in this period of
time the machine can work
without any problem;
 If you press the mode
selection button
twice, you change the
value to "2 slush" that's to
say to the intermediate
product density level;
 Pressing the mode
selection button again
, you change the value
to "3 slush" that's to say to
the maximum product
density level that can be
set by Big Biz;
 If you press this button
again
, you pass to the
cold drink mode; at this
point, Big Biz will preserve
the product with a 4°C +/-
1°C temperature.
 If you press this button
again
, you go back to
the starting point, that's to
say only with the active
augers but the cooling
system switched off.
, you

Publicité

Table des Matières
loading