Please note when programming:
Each switch on point is closely linked
to the following switch off point.
They should always be programmed in
pairs to avoid errors.
Attention: The shortest possible
switching interval is 1 minute!
Proceed as follows:
1. For 1 Channel set-up: Set sliding
switch  to position
.
P
The first switch point (switch on) is
displayed.
2. Press button 1...7 () to input the
day of the week (1=Monday,
7=Sunday) or blocks of days.
Continuous pressing of this button
allows you to select individual days
and the following blocks of days:
1 to 5
1 to 7
1 to 6
6 to 7
Arrows in the Display indicate days
of the week.
3. Press buttons h () and m () to
set the time.
4. Press button
():
P
The next switch point (switch off) is
displayed.
5. Repeat steps 2 to 4 as often as
required.
6. After setting the desired switching
times: Set sliding switch  to
position AUTO and sliding switch
 to position RUN.
The timer will now operate
according to the programmed
switching times.
Checking, changing and deleting
switching times
Set sliding switch  to position
1. Checking:
Press button
P
as often as
necessary to show the desired
switching point in the Display.
2. Changing:
Use button
P
to flag up the
desired modified location.
Press buttons 1...7 () to change
the day of the week.
Press buttons h () and m () to
change the switching time, as
described earlier.
3. Deleting:
Use button
P
to flag up the
desired modified location.
Then press button "-X->" () and
button
P
() simultaneously for
3-4 seconds.
The Display will show a flashing
0:00 and the switching point is
deleted.
If the check, change or deletion is
complete set the sliding switch  back
to position RUN.
-X-> Skip Function (soft-override)
The Skip Function changes the
switching mode of the appliance
connected until the next step of
program is reached.
For instance: if the appliance is in ON
mode, pressing the Skip-button (-X->)
will immediately turn it OFF and vice-
versa.
1. Set sliding switch  to position
RUN.
2. Press the Skip button (-X->).
The appliance will change over to
the opposite switching mode.
The Skip symbol (-X->) show up in
the Display (wait 3-4 seconds).
3. Further pressing of the Skip button
(-X->) brings up the Skip Function
again.
Please note in connection with the
Skip Function:
 Display of the number and the
symbol occurs after a lapse of about
3 seconds.
 The Skip Function only operates until
the next programmed switch time is
reached. At this point the Skip
Function is deleted and the
programmed switch time cycles are
activated again.
Programming Errors
Every switch on point is closely linked
to the following switch off point.
P
.
Therefore the following combinations
of on/off switching can, for example,
lead to errors.
Possible sources of errors are:
Switch ON
Time
Switch ON time
a)
programmed
b) No setting
Day block (e.g. 1,
c)
2, 3, 4, 5)
d) Day block
Switch ON time
programmed
e)
(e.g. Wednesday,
09:00)
ON and OFF switch times occur at
f)
the same time (e.g. Wednesday,
09:00)
- 43 -
Switch OFF
Time
No setting
Switch OFF time
programmed
Different day
block (e.g. 1, 2, 3,
4, 5, 6)
Week day
Switch OFF time
is before the
switch ON time
on the same day
(e.g. Wednesday,
08:59)