Display
Parameter
CP. 0
Password input
CP. 1
Actual frequency display -
CP. 2
Inverter status display
CP. 3
Actual load
CP. 4
Peak load
CP. 5
Rated frequency
CP. 6
Boost
CP. 7
Acceleration time
CP. 8
Deceleration time
CP. 9
Minimal frequency
CP.10
Maximal frequency
CP.11
Fixed frequency 1
CP.12
Fixed frequency 2
CP.13
Fixed frequency 3
CP.14
Max. ramp current
CP.15
Max. constant current
CP.16
Speed search
CP.17
Voltage stabilization
CP.18
Slip compensation
CP.19
Autoboost
CP.20
DC-braking
CP.21
Braking time
CP.22
Relay output
CP.23
Frequency value
CP.24
Reference signal (only C) 0...2
The function key (FUNC) changes between the
parameter value and parameter number.
With UP and DOWN the value of the parameter number
is increased/decreased with changeable parameters.
Password input:
Barring the
Password
CP-Parameter
FUNC
Adjust. range
0...9999
-
-
-
0...409.58 Hz
0...25.5 %
0.01...300 s
0.01...300 s
0...409.58 Hz
0...409.58 Hz
0...±409.58 Hz
0...±409.58 Hz
0...±409.58 Hz
10...200 %
10...200 %
0...15
150...649 V,off
-2.50...2.50
-2.50...2.50
0...9
0...100 s
0...xx
0...409.58 Hz
ENTER
UP
Quick referenz
Resolution
1
0,1 Hz
-
1 %
1 %
0.0125 Hz
0.1 %
0.01 s
0.01 s
0.0125 Hz
0.0125 Hz
0.0125 Hz
0.0125 Hz
0.0125 Hz
1 %
1 %
1
1 V
0.01
0.01
1
0.01 s
1
0.0125 Hz
1
STOP
START
Releasing the
Password
CP-Parameter
FUNC
Customer setting
-
-
-
-
-
____________
____________
____________
____________
____________
____________
____________
____________
____________
____________
____________
____________
____________
____________
____________
____________
____________
____________
____________
____________
FUNC.
SPEED
STOP
START
ENTER
UP
GB
43

Publicité

loading