1.2.5 Outputs
When
using
consumers at the relay output
a protective wiring (i.e. free
wheeling diode) is necessary
to protect the relay!
2. Operation of the unit
2.1 Digital operator
Part-No. 00.F4.010-2009
2.1.1 Interface operator
Part-No. 00.F4.010-1009
5 4 3 2 1
9 8 7 6
inductive
1
2
Relay output:
30V DC / 0,01...1A
As an accessory to the local operation an operator is necessary. To
prevent malfunctions, the inverter must be brought into nOP status
before connecting/disconnecting the operator (open control release
terminal X1.19 C-Version/X1.14 S-Version). When starting the inverter
whitout an operator, it is started with the last stored values or factory
setting. The operator is obtainable in different versions:
Interface control
Transmit "LED flickers"
In the Interface operator there is an additionally isolated RS232/RS485-
Interface integrated.
PE-Connection
PIN
RS485
1
2
3
4
A'
5
B'
6
7
C/C'
8
A
9
B
Informations about other versions of operators contact KEB!
Installation and Connection
3
9 10
+
5-digit LED Display
Double function keyboard
Signal
Meaning
reserved
TxD
Transmitter signal/RS232
RxD
Receiver signal/RS232
RxD-A
Receiver signal A/RS485
RxD-B
Receiver signal B/RS485
VP
Voltage supply-Plus +5V (I
DGND
Data reference potential
TxD-A
Transmitter signal A/RS485
TxD-B
Transmitter signal B/RS485
PE
Analog output:
0...10VDC / max. 5mA
at Ri ≥ 56 KΩ const.
Operating-/Error display
Normal "LED on"
Error "LED blinks"
RS232/RS485
= 10 mA))
max