Télécharger Imprimer la page

KEB COMBIVERT F4-C Manuel D'instruction page 39

Masquer les pouces Voir aussi pour COMBIVERT F4-C:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 44
Relay output
Frequency value
Relay output (terminal X1.1...X1.3) is adjusted in the factory as a fault
relay. This parameter can adjust the function of the output onto any
function listed in the table below.
Value
Function
0
No function
1
Generally on
2
Fault relay
3
Fault relay (not at under voltage error)
4
Overload alert signal (10s before switch off)
5
Overtemperature alert signal inverter
6
Overtemperature alert signal motor (10s before switch off)
7
Only for application-mode
8
Max. constant current (stall, CP.15) exceeded
9
Max. LA-/LD-Stop (CP.14) exceeded
10
DC-braking active
11
Only for application mode
12
Rate of utilization (CP.3) > 100%
13
Only for application mode
14
Actual value=set value (CP.2 = Fcon, rcon; not at noP, LS, error, SSF)
15
Accelerate (CP.2 = FAcc, rAcc, LAS)
16
Decelerate (CP.2 = FdEc, rdEc, LdS)
17
Right handed rotation (not at noP, LS error)
18
Left handed rotation (not at noP, LS error)
19
Real direction of rotation = set direction of rotation
20
Real value > frequency level CP.23 (only version S)
21
Set value > freqeuncy level CP.23 (only version S)
22
Only for application-mode
23
Operating signal (after initialization as long as no error is active)
24
Run signal
25...xx Only for application-mode
Factory setting:
Note:
Customer adjustment:
This parameter determines the switching point for the relay output
- X1.21...X1.23 (only version C)
- X1.1...X1.3 (only version S at CP.22 = "20" or "21").
After the switching of the relay, the frequency can move within a 0.5 Hz
window, without the relay dropping off.
Adjustment range:
Resolution:
Factory setting:
Customer adjustment:
2
Enter-Parameter
_______
0.0...409.58 Hz
0.0125 Hz
4 Hz
_______
GB
39

Publicité

loading