Cleaning The Air Filter; Maintenance; Daily Maintenance; Lubricating The Upper Packings - Titan AirCoat Série Mode D'emploi

Masquer les pouces Voir aussi pour AirCoat Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Cleanup
5.3

Cleaning the air filter

The air filter blocks any debris or particles that might be present in
the supplied air from the air compressor. It is important that this filter
be checked after every use.
1. Follow the "Pressure Relief Procedure" found in the Operation
section of this manual, section 4.7.
2. Remove the top four screws that secure the front shroud. The
two screws at the bottom front do not need to be removed.
3. After the four top screws are removed, flip open the front
shroud.
4. Remove the larger tube from the quick-lock fitting on the air
inlet fitting (Fig. 14, item 1). The other end of the tube can
remain connected. It can be twisted within the bottom fitting
so that it will be out of the way.
5. Unthread the filter bowl (2) that is located underneath the air
motor shroud. Be careful not to lose the O-ring (3) that may
fall out of the bowl. The clear tube may slip off of the fitting
on the bottom of the housing. It can be reinstalled later.
For model 620 units, press the red lock release on
i
the gray shroud and turn 1/4 turn counterclockwise
to remove.
6. Unthread the filter assembly from the sprayer. Be careful not
to lose the cap (4), spring (5), filter (6) or stem (7).
7. Remove and inspect the filter (P/N 0533557, 6). If dirty, clean
with warm, soapy water.
8. Prior to reassembly, tilt the sprayer on its back.
9. Make sure all parts of the filter are reassembled prior to
reinstallation (fig. 14, items 4-7).
10. Thread the entire filter assembly back into its housing in the
sprayer.
11. Make sure the O-ring (3) is in place. Thread the bowl into
position underneath the motor shroud.
Model 620 - with the bowl inside the shroud, insert into place
and turn clockwise until the two parts lock into place. Make
sure the red lock release is facing towards the front of the
sprayer.
12. Flip the front shroud back into place and secure with the four
top screws.
1
4
5
6
7
3
2
AirCoat
GB
6.

Maintenance

Before proceeding, follow the Pressure Relief
Procedure outlined previously in this manual.
Additionally, follow all other warnings to reduce the
risk of an injection injury, injury from moving parts
or electric shock. Always unplug the sprayer before
servicing!
6.1

Daily Maintenance

Two daily procedures are required for routine operator maintenance
on this sprayer:
A. Lubricating the upper packings.
B. Cleaning the inlet screen
A) Lubricating the upper Packings
1. Clean out the paint that has seeped past the upper packings
into the packing oil reservoir (fig. 15, item 1) above the fluid
section.
2. Fill the packing oil reservoir 1/2 full with Piston Lube (P/N 314-
480) supplied by the factory. This will extend packing life.
i
Do not over-fill the reservoir so that it overflows and
drips into the paint.
B) Cleaning the Inlet Screen
1. The inlet screen will clog and must be cleaned at least once a
day.
2. Loosen and remove the inlet screen (1) from the bottom of
the metal suction tube.
3. Clean thoroughly with the appropriate solvent.
13