DeWalt D55371 Guide D'utilisation page 20

Compresseur d'air portatif avec la pompe scellée et lubrifiée
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CoDe
PossIble CAuse
15
Tank pressure exceeds pressure switch cut-in
pressure
16
Extension cord is wrong length or gauge
17
Loose electrical connections
18
Possible defective motor
19
Paint spray on internal motor parts
20
Fuse blown, circuit breaker tripped
21
Restricted air intake filter
22
Defective pilot valve
PossIble solutIon
Motor will start automatically when tank pressure drops below
cut-in pressure of pressure switch.
Check for proper gauge wire and cord length. Refer to the
extension Cords paragraph in the Installation section.
Contact a D
WALT factory service center or a D
e
rized service center.
Contact a D
WALT factory service center or a D
e
rized service center.
Contact a D
WALT factory service center or a D
e
service center. Do not operate the compressor in the paint spray
area. See flammable vapor warning.
1. Check fuse box for blown fuse and replace as necessary.
Reset circuit breaker. Do not use a fuse or circuit breaker with
higher rating than that specified for our particular branch cir-
cuit.
2. Check for proper fuse. You should use a time delay fuse.
3. Check for low voltage conditions and/or proper extension
cord.
4. Disconnect the other electrical appliances from circuit or oper-
ate the compressor on its own branch circuit.
Clean or replace air intake filter. Do not operate the air
compressor with the filter removed. Refer to the Air filter
paragraph in the Maintenance section.
Replace pilot valve. Contact a D
D
WALT authorized service center.
e
20
WALT autho-
e
WALT autho-
e
WALT authorized
e
WALT factory service center or a
e

Publicité

Table des Matières
loading

Table des Matières