Order List - Dräger X-plore 5500 Notice D'utilisation

Masque complet
Masquer les pouces Voir aussi pour X-plore 5500:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 30
Storage
Loosen the straps as far as possible.
Wipe lens with anti-static cloth.
Pack full-face mask in its bag or box.
Store it in a dry, dust-free place where it is not deformed.
o
Storage temperature: –15
C to 35
Keep out of direct sunlight and heat.
Maintenance Intervals
Work to be carried out
Inspection by wearer of device
Cleaning and Disinfection
Visual inspection, function and
leak tests
Replacing the exhalation valve
disc
Replacing the speech diaphragm
Replacing the O-ring of the
speech diaphragm
1) Full-face masks in airtight packaging, otherwise every six months.
2) Full-face masks in airtight packaging every 2 years.

Order List

Designation and description
Dräger X-plore 5500
Dräger X-plore 5500 L
Spare parts
Lens for Dräger X-plore 5500
Lens for Dräger X-plore 5500 L
Head strap
Control valve
Exhalation valve disc
Inhalation valve disc
Protective cap (black)
Cap
Cleaning and disinfecting agents
1008 GREEN LIQUID HAND DISH WASH
800 SPUR-TEX Disinfectant
NEUTRAL DISINFECTANT CLEANER
Contact Dräger for accessories such as spectacle kits, welding
shield, anti-fogging agents, storage bags, etc.
o
o
o
C (5
F to 95
F)
Maximum intervals
X
1)
X
X
2)
X
X
X
Order No.
R 55 270
R 56 655
R 50 833
R 26 989
R 26 279
RM 08 304
R 52 541
R 51 488
R 52 552
R 55 268
on request
on request
on request
Use instructions for NIOSH-approved full facepieces
X
X
29