26 | FSA 740 | Technical data
7.1.4

Oscilloscope measuring functions

Measuring functions
Measuring range
Secondary voltage
5 kV – 50 kV
Primary voltage
20 V – 500 V
Voltage
200 mV – 200 V
AC coupling
200 mV – 5V
Current
2 A
5 A
10 A
20 A
30 A
Current
50 A
100 A
200 A
1000 A
The measuring range is positive or negative depending on the
*)
zero line.
7.1.5

Oscilloscope functions and specifications

Function
Specification
Input coupling
AC/DC
CH1/CH2
Input impedance
1 MOhm
CH1/CH2
(relative to ground)
Input impedance
1 MOhm (5 — 200 V)
CH1/CH2
10 MOhm (200 mV — 2 V)
(galvanically insulated)
Input impedance
4 MOhm
CH2 (switchover)
Bandwidth CH1
> 5 kHz = 200 mV – 2 V
(galvanically insulated)
> 25 kHz = 5 V – 200 V
Bandwidth CH1 (re-
> 1 MHz = 200 mV – 2 V
lative to ground)
> 5 MHz = 5 V – 200 V
Bandwidth CH2 (re-
> 1 MHz = 200 mV – 2 V
lative to ground)
> 5 MHz = 5 V – 200 V
Bandwidth CH2
> 30 kHZ
(differential mea-
surement)
Bandwidth 1000 A
> 1 kHz
current clamp
Bandwidth 30 A cur-
> 50 kHz
rent clamp
Bandwidth secondary
> 1 MHz
sensor
Bandwidth connec-
> 100 kHz (20 V)
ting cable term . 1
> 1 MHz (50 V – 500 V)
Time ranges (relative to
10 µs – 100 s
500 scanning points)
Time ranges (relative
20 ns – 200 ms
to 1 scanning point)
Time basis accuracy
0,01 %
Vertical accuracy
±2 % of reading
Device without sensors
±0,3 % of measuring range
(Offset error for ranges > 1 V)
or ±5 mV
(offset error for ranges
200 mV – 1 V)
1 689 979 895
|
2008-02-25
Function
Vertical resolution
Memory depth
Sensors
*)
Secondary
Scan rate per channel
sensor
Connecting ca-
ble term . 1
7.2
Multi measuring
cable CH1 / CH2
Function
Connecting ca-
ble B+/B–
Amplitude
Current
clamp 30 A
Signal shapes
Frequency range
Output current
(load-dependent)
Current clamp
Impedance
1000 A
Symmetry
Curve generation
Short-circuit resistance
to interference voltage
Short-circuit resistance
to interference voltage
R
R
7.�
Function
Input voltage:
Input frequency
Output voltage
Operating temperature
7.4
< 70 dB(A)
7.5
Function
Dimensions H x B x T:
Weight
Specification
10 bit
1 Mega scan values or 50 curves
50 Ms/s

Signal generator

Specification
-10 V – 12 V
(load < 10 mA) to ground
DC, sinus, triangle, square
1 Hz – 1 kHz
30 mA – 75 mA
ca . 60 Ohm
10 % – 90 %
(triangle, square)
Output rate up to 100,000 values/s,
Resolution 8 bit,
Y-full range adjustable ( bit),
Unipolar / bipolar mode .
< 50 V static
< 500 V / 1 ms dynamic
Automatically switched filter and damping elements
for improvement of signal quality .
Automatic cutoff at short circuit, interference voltage
detection at start of signal generator .

Power pack

Noise emissions

Dimensions and weights

Specification
90 VAC – 264 VAC
47 Hz – 63 Hz
15 V
0 °C – 40 °C
Spezifikation
1785 x 680 x 670 mm
91 kg
Bosch Diagnostics