Fast Track Kit Troubleshooting Guide
CAUTION: Always disconnect power cord before servicing.
WARNING: Repairs should only be performed by an authorized service center.
1. Cap is damaged
2. Faulty vacuum motor
3. Micro-Ply filter bag is full
4. Clogged hose, wand or base cover ports
5. Loose or broken fan
1. Faulty ON/OFF switch
2. Power cord defective
3. Loose connection or wiring
4. Motor defective
5. Blown fuse or tripped circuit breaker
1. Micro-Ply filter bag is full
2. Micro-Ply filter bag not installed properly
3. Cloth filter bag dirty
4. Cloth or Micro-Ply filter bag is torn
8
Parts & Operations Manual
Loss of suction
CAUSE
Motor is not running
CAUSE
Dust blowing from vacuum when running
CAUSE
Integra-D
PROBLEM:
1. Inspect and replace if needed
2. Contact Dustbane or a service center
3. Replace Micro-Ply filter bag
4. Remove obstruction
5. Contact Dustbane or a service center
PROBLEM:
1. Contact Dustbane or a service center
2. Contact Dustbane or a service center
3. Contact Dustbane or a service center
4. Contact Dustbane or a service center
5. Replace fuse or reset circuit breaker
PROBLEM:
1. Replace Micro-Ply filter bag
2. Reinstall or replace
3. Clean cloth filter bag
4. Replace
SOLUTION
SOLUTION
SOLUTION