plug back into the hole securely afterwards. Otherwise, there may be a leak when
you use the device again.
Displays
Both displays (top and front) show the air humidity in the room.
If you enter the desired air humidity, this setting will be shown for a few seconds.
If you set an ON/OFF time using the timer, the display will show the set number of
hours for a few seconds.
If the air humidity is lower than 35%, the display will show 'LO' (low)
If the air humidity is higher than 95%, the display will show 'HI' (high)
Operation panel
1.
[Swing] button
This button can be used to tilt the air outlet up and down for better air circulation in
the room.
2.
[Pump] button (See installation)
With this button a pump can be switched on to pump out the water. The water is
collected in the water tank as standard when the short preformed hose is mounted.
When you connect a 10 mm drain hose, the water can be drained to a drainage
point so that the water tank does not have to be emptied every time. The
maximum delivery head of this pump is 3 meters.
Note: If you use continuous drainage, always check to ensure there are no
leaks in the hose connection before you leave the device unattended.
Note: switch the pump on ONLY if the drainage hose is installed or if the
short, pre-shaped hose that is supplied on the rear of the device is
installed and goes to the water tank. If you switch the pump on without a
hose installed, the water will flow out of the water outlet and onto the
floor, where it could cause damage.
3.
[TIMER] button
The timer button is used to set the times at which the device must come on and go
off. Press the Timer button and the light will go on. If you do this while the device is
22