P CONT MODE
In this transmission mode the instrument transmits continuously the following data format:
ST,GS,XXX.XXXXkg<CR><LF>
U.W.XXXXXXXXXXg<CR><LF>
PCSXXXXXXXXXXXpcs<CR><LF>
<CR><LF>
SEr rE MODE
In this transmission mode the instrument transmits continuously the following data format:
ST,GS,XXX.XXXXkg<CR><LF>
<CR><LF>
9.2 FORMAT OF THE SERIAL COMMANDS
9.2.1 BASIC COMMANDS
COMMAND
PLUxx<CR><LF>
T<CR><LF>
Txxx.xxx<CR><LF>
Z<CR><LF>
M+<CR><LF>
MR<CR><LF>
MC<CR><LF>
Uxxx.xxx<CR><LF>
Sxxx<CR><LF>
SL<CR><LF>
SR<CR><LF>
9.2.2 STORAGE COMMANDS
COMMAND
SUIDxxxxxx<CR><LF>
SSIDxxxxxx<CR><LF>
SSIDnn,xxxxxxxxxxxx<CR><LF>
GS for gross weight, NT for net weight
Average piece weight
Number of pieces
GS for gross weight, NT for net weight
FUNCTION
PLU selection, in which xx is the number of the PLU to be selected.
Automatic tare, tares the weight on the scale.
Manual tare, in which xxx.xxx is the tare to be entered. If the tare is not valid the
instrument emits an acoustic signal and clears the eventual tare.
Clears the gross weight.
Executes the totalisation with printing.
Displays the accumulated total.
Clears the accumulated totals and the totalisation progressive.
Entry of APW (in grams if the unit is "kg" or pounds if the unit is "lb") in which xxx.xxx is
the apw to be entered. If the APW is not valid the command clears the eventual APW.
Executes the sampling with the set number of pieces, in which xxx is the number of
pieces.
Selects the local scale.
Selects the remote scale.
FUNCTION
Setting user ID, in which xxxxxx are the 6 alphanumeric characters of the id.
Setting scale ID, in which xxxxxx are the 6 alphanumeric characters of the id.
Setting PLU, in which nn is the number of PLU and xxxxxxxxxxxx are the 12
alphanumeric characters of the description (only the characters which can be entered
with the keyboard are allowed, the others are entered as spaces)
19