PROCEDURE WITH DEFINED SAMPLE WEIGHT
- Enter 9999 and press the PST key:
- One will be asked to select the scale to be calibrated: leave "LoCAL" (local scale) or press the LOCAL/REMOTE key to
select "rEMotE" (remote scale).
- Confirm with TARE or press ZERO to exit without confirming.
- One will be asked to select the calibration unit of measure: leave "kg" or press U.WT/UNITS to select "lb".
- Confirm with TARE or press ZERO to exit without confirming.
- The display shows the acceleration value set: enter the gravitational acceleration value of the calibration zone, if
different from the use zone, by using the numeric keyboard One must modify all the 6 digits of the gravitational
acceleration.
- Confirm with TARE or press ZERO to exit without confirming.
- The display shows "UNLOAD";
- Unload the scale and press the TARE key when the stability indicator is on.
- The display shows "A XXyy" in which XX is the value and yy the unit of measure of the first sample weight to be used;
- Put the first sample weight, defined in the table below, on the scale and press TARE when the stability indicator is on;
- The display shows "A XXyy" in which XX is the value and yy the unit of measure of the second sample weight to be
used;
- Put the second sample weight, defined in the table below, on the scale and press TARE when the stability indicator is
on;
- The indicator returns to the weighing mode.
MODEL
1° WEIGHT
2° WEIGHT

9. SERIAL OUTPUT

Specifications
RS-232 output for the transmission of the weight data
ASCII code
Baud 4800 (selectable from 600 - 9600)
8 data bits (selectable at 8 – n – 1, 7 – E – 1, 7 – o – 1)
No Parity
Connector: 9 pin (female)
Pin 2:
RECEPTION
Pin 3:
TRANSMISSION
Pin 5:
GND
CALIBRATION WEIGHTS
BCSD6
2 kg
6 kg
BCSD15
5 kg
15 kg
17
BCSD30
10 kg
30 kg