7.2 "F1 oFF" – SETTING DISPLAY BACKLIGHTING, ACOUSTIC ALARM AND UNITS OF MEASURE
bEEP
ACOUSTIC ALARM
on oFF acoustic alarm disabled
on in
active acoustic signal with active "OK" symbol.
on oUt active acoustic signal with active "HI" or "LO" symbol.
EL DISPLAY BACKLIGHTING
oFF
backlighting always off
on
backlighting always on.
AUt
backlighting on only when the weight is greater than 20d or when a key is pressed. When a key is pressed,
if the weight is less than 20d, the backlighting remains active for 5 seconds.
Unit
UNIT OF MEASURE
Trough this step it's possible to select the units of measure usable in the weighing phase (see section 6.2).
kG/Lb
"kg" and "lb" units both active
kiLo
only "kg" unit active.
Lb
only "lb" unit active.
oFF
AUTO SWITCH-OFF
By pressing TARE one sets the minutes of not being used for the auto switch-off (see section 6.12):
0
(disabled)
3
(3 minutes of not being used)
5
(5 minutes of not being used)
15
(15 minutes of not being used)
30
(30 minutes of not being used)
7.3 "F2 Prt" – PRINTER CONFIGURATION
P ModE TRANSMISSION MODE
Print
transmission when totalisation is made or upon request through serial command.
By selecting this mode one will be asked to select the totalisation mode:
AU oFF Manually through the M+ key.
AU on
P Cont continuous transmission with P Cont. protocol
SEr rE continuous transmission with SEr rE. protocol
For the description of the transmission modes refer to section 9.1.
P bAUd TRANSMISSION SPEED
Press the U.WT/UNITS key to select one of the possible speeds : 600, 1200, 2400 4800, 9600.
PAritY
SETTING PARITY, WORD, STOP BIT
Press the U.WT/UNITS key to select one of the possible values: 8 n 1, 7 E 1, 7 o 1.
PtYPE
PRINTER TYPE
tPuP
enables the printing with ASCII printer (for example TPR).
LP50
Non used in this application.
7.4 "U id" - SETTING USER ID
By pressing TARE it's possible to enter or modify the USER ID, in other words, a text of 6 characters which can be
printed or recalled through the serial line (see section 9.2.3).
To enter the text refer to section 6.10.
Automatically upon weight stability
14