Print Command; Tpr Printer Connection - Dini Argeo BCSD Serie Manuel Opérateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

9.2.3 PRINT COMMAND

COMMAND
TRANSMITTED DATA
\L<CR><LF>
LOCAL SCALE<CR><LF>
\I<CR><LF>
ID: xxxxxx<CR><LF>
\S<CR><LF>
SCALE: xxxxxx<CR><LF>
\N<CR><LF>
bxxx.xxxbUMbNET<CR><LF>
\G<CR><LF>
bxxx.xxxbUMbGROSS<CR><LF>
\T<CR><LF>
bxxx.xxxbUMbTARE<CR><LF>
\U<CR><LF>
bxxx.xxxbUMbU.W.<CR><LF>
\P<CR><LF>
bbxxxxxxbPCS<CR><LF>
\C<CR><LF>
bbxxxxxxbTPC<CR><LF>
\W<CR><LF>
bxxx.xxxbUMbTW<CR><LF>
\M<CR><LF>
bbxxxxxxbNO<CR><LF>
\B<CR><LF>
<CR><LF>
<CR><LF>
Legend:
b = ascii 32 space character
<CR><LF> = Carriage Return + Line Feed (ASCII 13 and 10 characters).
UM = unit of measure of the active scale (kg, lb).
Note: <LF> is optional. If the command or syntax is incorrect or the value is expressed incorrectly (for example a numeric
value expressed with a comma instead of with a point) the instrument transmits "ER" + the transmitted command.

9.3 TPR PRINTER CONNECTION

STANDARD
TPR
GND
Black
CTS
Yellow
RX
Grey
TPR printer power supply
STANDARD
+VP and +VC
Red and Orange
GND and GND
Black and Black
NOTES:
- Set baud rate at 600 in the TPR (TPR Manual ref.).
- Set the following parameters in the BCSD (see section 7):
P ModE >> Print >> AU oFF or AU on
P baud >> 600
PtYPE >> tPuP
BCSD
CABLE
(9 Pin connector)
GND
- (not connected)
TRANSMISSION
POWER SUPPLY
CABLE
+V (5V / 5A)
- V
DESCRIPTION
Selected scale, "LOCAL" for the local scale, "REMOTE" for the
remote scale.
USER ID, in which xxxxxx are the 6 set characters (see section
7.4).
SCALE ID, in which xxxxxx are the 6 set characters (see section
7.5).
Net weight, with spaces for the non significant zeros in front.
Gross weight, with spaces for the non significant zeros in front.
Tare weight, with spaces for the non significant zeros in front.
Average piece weight, with spaces for the non significant zeros in
front.
Number of pieces, with spaces for the non significant zeros in
front.
Total Pieces, with spaces for the non significant zeros in front.
Accumulated total weight, with spaces for the non significant
zeros in front.
Totalisation progressive, with spaces for the non significant zeros
in front.
2 <CR><LF>
20

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Bcsd6Bcsd15Bcsd30

Table des Matières