5.2) Purging air bubbles from the internal hydraulic circuit
The operations of connecting and disconnecting the fl exible hose and hydraulic heads
could cause air bubbles to form in the hydraulic circuit over time, adversely affecting the
performance of the pump.
To purge air bubbles from the circuit proceed as follows:
– Connect the hose and the hydraulic head to the pump.
– Place the hydraulic head onto a fl at surface, keeping it in a vertical position.
– Leave the pump in inclined position (see Fig. 8) at a height approximately 1,5 m (4.9 ft)
higher than the head.
– Operate push button until the pressure switch intervenes.
– Completely discharge the oil pressure pushing the release button.
– Repeat at least 3-4 times to ensure all bubbles collect in the upper part of the reservoir.
– Check the oil level, topping up if necessary (see § 5.1).

6. FAULT DIAGNOSIS

SYMPTOM

POSSIBLE CAUSES

Discharged battery.
The pump does not start
when the remote controller
push button.
Incorrect connection of the
remote controller plug.
T h e p u m p s t a r t s b u t
Incorrect connection of the high
immediately stops.
pressure hose to the pump or
to the hydraulic head.
The pump starts but the oil is
Insuffi cient oil in the reservoir.
not pressurised.
No advancement, slow or
Air in the internal hydraulic
pusating advancement of
circuit of the pump.
the ram of the hydraulic head
connected to the pump.
The thermal switch has trig-
After long use the pump will
gered because of motor ove-
not start.
rheating.
It is not possible to couple the
Residual pressure of the oil in
fl exible hose to the pump.
the hose.
If after these actions, the pump still does not operate correctly, please return it to Cembre
(see § 7).
8
ENGLISH
(Ref. to Fig. 8)
REMEDY
Charge the battery (see § 3.5)
Connect plug correctly and
secure with the locking bezel
(see § 3.1).
Check the quick couplers for
correct connection (see § 3.1).
Top up the oil reservoir
(see § 5.1).
Purge air bubbles in the internal
hydraulic circuit
(see § 5.2).
Allow the pump to rest and wait un-
til the motor has cooled down.
Connect the fl exible hose to
the pump keeping the release
button pushed.