AVENTICS | DDL, CL03/CL03-XL | R402003658–BDL–001–AE
Replacement
2
1
Fig. 6:
Replacing a multipole module with a bus coupler, example
8.2
Replacing a multipole module with a bus
coupler
Applied voltage and high pressure!
Danger of injury from electric shocks and sudden pressure
drops.
O
Make sure the system is not under pressure or
connected to power when you exchange a module.
1. Unscrew the three screws (1) that fit the multipole
connector module (2) to the valves (hexagonal head, wrench
size 8 mm).
2. Detach the module from the valve subbase (3).
3. Push the replacement bus coupler onto the tie rods (4) of the
valve unit. Make sure that the seal (5) is fitted correctly.
4. Refit and tighten the three screws (1). Tightening torque
2.8 to 3.2 Nm.
5. Make all the settings on the bus coupler
(see "Making settings" on page 67).