AVENTICS | DDL, CL03/CL03-XL | R402003658–BDL–001–AE
Commissioning and Operation
S6
ON
OFF
2. Make the settings with the switches as described below.
3. Refit the cover carefully according to Fig. 4 below. Ensure
that the sealing (2) is positioned correctly. Tighten the
screws (1) with a torque of 1.0 to 1.2 Nm.
S1
S6
S5
Fig. 4:
Removing/fitting the cover of the bus coupler

7.1.1 Setting the data rate (DDL mode)

All participants in a DDL line must be set to the same data
rate (baud rate).
Changes during operation
Changes to the DDL mode are only taken over after a voltage
reset.
O
Never change the settings during operation.
O
Turn the device off before changing the address setting.
O
Set the data rate with the S6 DIP switch, bit 1.
NOTICE
1
2