Connect Gas Supply; Connect Electrical Supply - Bosch NGMP0777UC Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5. Allow the silicone sealant to dry before using the
appliance.

Connect Gas Supply

Side View Gas Cooktop Installation
Gas and Electrical Location
A
Cooktop Rough-in Box
B
Arrow on Pressure Regulator
C
Pressure Regulator
D
1/2" Female Pipe Threads
E
Flexible Gas Line
G
Power Cord (40"/1 m)
H
120 Volt Receptacle
J
Gas Cut-off Valve
K
Gas Supply Line Stub-out
L
Floor
Installing the Pressure Regulator
WARNING
Do not attempt any adjustment of the pressure
regulator, except when converting to propane.
Adjustments could lead to leaks or cause incorrect
gas pressure to the appliance.
Install the pressure regulator (supplied with unit) to
manifold pipe using Teflon tape on threads of manifold
pipe. Turn to hand tighten plus 1/4 turn, not exceeding
1 turn for alignment.
To prevent possible damage to the gas pressure
regulator, install it after the cooktop is in its permanent
position. When the regulator is securely installed on the
manifold pipe, the conversion nut will be easily
accessible.
For tight installations a suitable kit is available from
Customer Service (order no. 00611084)
10
A
Appliance Manifold Connection
B
Conversion Nut
C
Pressure Regulator
Connecting the Gas Supply Line
Connect the gas supply line to the unit pressure
regulator using a 1/2" flex gas line connector between
manual shut-off valve and pressure regulator. Always use
a new flex line.
Checking Gas Line for Leaks
Check supply line connections for leaks using a soap
solution or non-corrosive leak detection fluid. Do not use
a flame of any sort.
1. Turn on gas.
2. Apply a soap solution or non-corrosive leak detection
fluid to all joints and fittings in the gas connection
between the shut-off valve and the cooktop. Include
gas fittings and joints in the cooktop if connections
may have been disturbed during installation.
Bubbles appearing around fittings and connections
indicate a leak.
3. If a leak appears, turn off supply line gas shut-off valve
and tighten connections.
4. Retest for leaks by turning on the supply line gas shut-
off valve. When leak check is complete (no bubbles
appear), test is complete.
5. Wipe off all soap solution or detection fluid residue.
Important Notes for Gas Connection:
The appliance and its individual gas shutoff valve must
be disconnected from the gas supply piping system
during any pressure testing of that system at test
pressures in excess of 1/2 psi (3.5kPa).
The appliance must be isolated from the gas supply
piping system by closing its individual manual shut-off
valve during any pressure testing of the gas supply
piping system at test pressures equal to or less than
1/2 psi (3.5kPa).

Connect Electrical Supply

Before connecting the 40" (1 m) supply cord to a wall
receptacle, make certain that gas shut-off valve and all
burner controls are in OFF position.