Connect Gas Supply

The gas inlet to the unit is located at the right rear of the
cooktop.
Opening for Gas
Connection and
Electrical Cord
1"
Install the pressure regulator (supplied with unit) to
manifold pipe using Teflon tape on threads of manifold
pipe. Turn to hand tighten plus 1/4 turn, not exceeding 1
turn for alignment. To prevent possible damage to the gas
pressure regulator, install it after the cooktop is in its
permanent position. When the regulator is securely
installed on the manifold pipe, the conversion nut will be
easily accessible.
9 WARNING
Do not attempt any adjustment of the pressure
regulator, except conversion to propane..
Connect the gas supply line to the unit pressure regulator
using a 1/2" flex gas line connector between manual shut-
off valve and pressure regulator. Always use a new flex
line.
9001070914 Rev A
C of Cutout
L
9 3/16" (233 mm)
Figure 6: Cooktop Area
Figure 7: Pressure Regulator
Figure 8: Gas and Electrical Location
Check supply line connections for leaks using a soap
solution. Do not use a flame of any sort.
1. Turn on gas.
2. Apply a non-corrosive leak detection fluid to all joints
and fittings in the gas connection between the shut-off
valve and the range. Include gas fittings and joints in
the range if connections may have been disturbed
during installation. Bubbles appearing around fittings
and connections indicate a leak.
3. If a leak appears, turn off supply line gas shut-off valve
and tighten connections.
4. Retest for leaks by turning on the supply line gas shut-
off valve. When leak check is complete (no bubbles
appear), test is complete.
5. Wipe off all detection fluid residue.
Important Notes for Gas Connection:
The appliance and its individual gas shutoff valve must
be disconnected from the gas supply piping system
during any pressure testing of that system at test
pressures in excess of 1/2 psig (3.5kPa).
The appliance must be isolated from the gas supply
piping system by closing its individual manual shut-off
valve during any pressure testing of the gas supply
piping system at test pressures equal to or less than 1/
2 psi (3.5kPa).

Connect Electrical Supply

Before connecting the 5-foot (1.5 m) supply cord to a wall
receptacle, make certain that gas shutoff valve and all
burner controls are in OFF position.
English 7