The maximum depth of cabinet installed above cooktop
is 13" (33cm).
Depth from Back Wall
Cabinet 13" (33cm) max.
Hood Depth - 24" (61cm) max.
Above Counter - 30" (76 cm) min. to
Combustible Surface
NGM24 - 24" (61cm) min.
Centered Over Cooktop
18" (46cm) min.
Left Side
Rear Wall - 2" (5cm)
4" (10cm) min.
Installed Dimensions (from cooktop edges
Figure 1:
Countertop Requirements
min. 30"
(min. 762)
1/ 2
20 "
(520)
3/ 4
2 "
(70)
4"
(100)
measurements in inches (mm)
Mounting Requirements
Use the mounting brackets supplied. See "Install the
Cooktop" on page 6 for further details.
Ventilation Recommendations
We strongly recommend the installation of a ventilation
hood above this appliance. The hood must be installed
according to instructions furnished with the hood.
9001070914 Rev A
Right Side
4" (10cm) min.
1" (25)
1"
23"
(25)
(582)
gas
connection
min. 3"
(min. 76)
7/ 8
20 "
(529)
1/ 4
19 "
(487)
max.3"
4"
(max. 76)
(100)
3/ 4
1 "
(45)
NOTE:
All measurements given have to be precisely followed. If
nonstandard cabinets are used, make sure they are
installed with minimum dimensions shown in Figure 1 and
Figure 2.
Plan the installation of the unit so that the power cord, gas
shut-off valve and gas pressure regulator are accessible
from the front of cabinet.
)
Island Installation
3"
(76.2)
Front
2 1/8"
(54)
Note: The appliance should not be installed with a
ventilation system that blows air downward toward the
burners. This type of ventilation system may cause ignition
and combustion problems with the gas cooking appliance
resulting in personal injury or unintended operation.
3 1/8"
Back
(79.4)
3"
(76.2)
measurement in inches/mm
Figure 2: Cutout Dimensions