Installation

Before You Begin

Tools and Parts Needed

1. Phillips Head Screwdriver
2. Tape Measure
3. Teflon Tape (Gas Rated)
4. Adjustable wrench or channel lock pliers

Parts Included

1. Foam tape
2. Hold down brackets (4)
3. Screws, #10-32 x 2 1/2" (63.8 mm) (4)
4. Sheet Metal Screws, #8 x 3/8" (9.5 mm) (4)
5. Washers (4)
6. Burner Grates (2)
7. Burner Caps (4)
8. Pressure Regulator
9. LP Gas Conversion Kit
If parts are missing or damaged, call the number or write to
the address listed inside the back cover.

General Information

Overall Dimensions
Width (Side
23"
to Side)
(582 mm)
Depth (Front
20.5"
to Back)
(520 mm)
Height (Top
3.75"
to Bottom)
(95 mm)
NOTE:
These are overall dimensions NOT cutout dimensions.
English 4

Preparation

Electrical Requirements
9 CAUTION
Do not use an extension cord with the gas cooktop.
This appliances requires a 60 Hz, 15 Amp, 120 VAC
connection. Plan the installation so that the power
connection is accessible from the front of the cabinet.
Gas Requirements
Supply Pressure:
Natural Gas - 7 inches water column (14.9 Millibars)
minimum.
Propane Gas -11 inches water column (27.4 Millibars)
minimum.
The propane gas tank must be equipped with its own high
pressure regulator in addition to the pressure regulator
supplied with this unit. The cooktop is shipped from the
factory for use with natural gas. For use with LP conversion
a qualified technician or installer must do the conversion.
Cabinet Requirements
Dimension requirements in Figures 1 and 2 are for
combustible surfaces. When the surface is protected by a
material listed by UL as a Floor Protector and Wall Shield
covered with not less than No. 28 MSG sheet metal 0.015
inch (0.38mm) stainless steel, 0.024 inch (0.6mm)
aluminum or copper, it is considered noncombustible and
some dimensions may be reduced. For a noncombustible
surface over the cooktop, the minimum clearance is 24"
(61cm) rather than 30" (76cm).
Instructions are based on standard American cabinets
36" high (91cm) x 24" deep (61cm) with a 25" (63cm)
countertop.
9001070914 Rev A