Hydraulic Connections; Installation For Dosing Liquid Detergent - aqua DGTEC CD Mode D'emploi

Masquer les pouces Voir aussi pour DGTEC CD:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 70
dGdoser Model
Programmable digital peristaltic pump

2.5 HYDRAULIC CONNECTIONS

The CD model enables the dosage of liquid detergent by means of the peristaltic pump, or the dosage of solid
detergent by piloting the solenoid valve, which, by regulating the water flow into the dispenser containing the
detergent, whether it is granular or in tabs, enables it to dissolve and enter the tank.
2.5.1

INSTALLATION FOR DOSING LIQUID DETERGENT

Make sure the suction tube is placed in the product container and then connected to the pump intake fitting
(marked with the ▲ symbol on the cover) and tightened with the correct ring nut.
Make sure the delivery tube is inserted in the pump delivery fitting (marked with the ▼ symbol on the
cover) and tightened with the correct ring nut. It must then be connected to the infeed fitting of the tank.
ADSP7000634
Fig. 7
Installation for dosing liquid detergent
rev. 1.2
INSTRUCTION AND MAINTENANCE MANUAL
30/06/2014
ENGLISH