Loosen the screws on the terminals (04) on the front
of the connector, insert the conductors and fasten
them tightening the screws. Screw in the body of the
connector (03) to the front with the terminals (05),
tightening the ring nut (06).
Pay attention to the fixing. Tightening
torque: from 0.29Nm up to 0.39Nm.
05
06
Fig. 22
Insert the gasket (02) inside the compartment of the
body of the connector (03). Lastly, fasten the sealing
nut (01).
03
Fig. 23
Pay attention to the fixing. Tightening
torque: from 0.39Nm up to 0.59Nm.
Fig. 24
Complete assembly.
20
04
04
03
02
01
Before fastening the mobile connectors to the
relevant connectors on the back of the camera,
ensure the TAPS correspond.
Fig. 25
Connect the mobile connector on the fixed
connector and tighten the ring nut.
8.2.2 Relays connection
The relay can be used with the
specifications outlined below.
• Working voltage: up to 30Vac or 60Vdc.
• Current: 1A max.
Use cables with the characteristics outlined
below.
• Section: from 0.14mm² (26AWG) up to
0.75mm² (18AWG).
The relay contacts are situated on the relevant quick
connector. The relays have no polarity (Tab. 3, page
19).
MNVCNVX_2110_EN