PILOT BURNER GOES OUT DURING USE.
Possible causes:
- Insufficient gas supply pressure.
- Defective gas tap or valve.
- Defective thermocouple or insufficient heating.
- Thermocouple incorrectly connected to gas tap or
valve.
-
Knob of gas tap or valve not pressed a.
THE MAIN BURNER DOES NOT LIGHT (EVEN
THOUGH PILOT IS LIT).
Possible causes:
- Insufficient gas supply pressure.
- Blocked tubing or nozzle.
- Defective gas tap or valve.
- Defective burner (gas outlet holes clogged).
HEATING CANNOT BE ADJUSTED.
Possible causes:
- Defective gas valve.
GAS FRY-TOP WITH VALVE
THE PILOT BURNER DOES NOT LIGHT.
Possible causes:
- Insufficient gas supply pressure.
- Blocked tubing or nozzle.
- Defective gas tap or valve.
- Igniter defective or not properly connected.
- Igniter or igniter wire defective.
PILOT BURNER GOES OUT DURING USE.
Possible causes:
- Insufficient gas supply pressure.
- Defective gas tap or valve.
- Defective thermocouple or insufficient heating.
- Thermocouple incorrectly connected to gas tap or
valve.
-
Knob of gas tap or valve not pressed a.
THE MAIN BURNER DOES NOT LIGHT (EVEN
THOUGH PILOT IS LIT).
Possible causes:
- Insufficient gas supply pressure.
- Blocked tubing or nozzle.
- Defective gas tap or valve.
- Defective burner (gas outlet holes clogged).
HEATING CANNOT BE ADJUSTED.
Possible causes:
- Defective gas valve.
ELECTRIC FRY-TOP
THE APPLIANCE DOES NOT HEAT.
Possible causes:
- Temperature thermostat defective.
- Heating elements defective.
- Safety thermostat tripped.
HEATING CANNOT BE ADJUSTED.
Possible causes:
- Temperature thermostat defective.
ELECTRIC OVEN
THE APPLIANCE DOES NOT HEAT.
Possible causes:
- Temperature thermostat defective.
- Heating elements defective.
- Safety thermostat tripped.
HEATING CANNOT BE ADJUSTED.
Possible causes:
- Temperature thermostat defective.

22. REPLACING COMPONENTS

REMINDERS FOR REPLACING COMPONENTS
SHUT THE GAS SHUT-OFF VALVE
AND/OR SWITCH THE APPLIANCE OFF
AT THE MAIN SWITCH INSTALLED
UPSTREAM.