REPLACING THE MINIMUM ADJUSTMENT SCREW
-
- Remove the control panel.
- Remove nozzle UM and replace it with the one
indicated in table TAB1.
- Retighten nozzle UM.
Reassemble all parts. For assembly, proceed in
reverse order.
- REPLACING THE PILOT BURNER NOZZLE
- Remove the control panel.
- Undo connector R.
- Remove nozzle UP and replace it with the one
indicated in table TAB1.
- Retighten connector R. Reassemble all parts.
- Following, in reverse order, the sequence used for
their removal.
- GAS FRY-TOP WITH VALVE
- REPLACING THE NOZZLE AND THE MAIN BURNER
PRIMARY AIR REGULATION
- Remove the control panel.
- Remove nozzle UM and replace it with the one
indicated in table TAB1.
Retighten nozzle UM.
- Slacken screw V and position the air regulator at
distance A as indicated in table TAB1.
- Retighten screw V fully.
- Reassemble all parts. For assembly, proceed in
reverse order.
- REPLACING THE PILOT BURNER NOZZLE
- Remove the control panel.
- Undo connector R.
- Remove nozzle UP and replace it with the one
indicated in table TAB1.
- Retighten connector R. Reassemble all parts.
- Following, in reverse order, the sequence used for
their removal.

9. COMMISSIONING

Following installation, conversion to a different
type of gas or any maintenance operations, check
appliance operation. In the event of any
malfunction, consult the next Paragraph "
Troubleshooting " .
GAS APPLIANCES
Switch on the appliance as directed in the
instructions and reminders for use given in Chapter
" INSTRUCTIONS FOR USE " and check:
- the gas supply pressure (see next Paragraph).
- the correct ignition of the burners and the
effectiveness of the fumes removal system.
- CHECKING THE GAS SUPPLY PRESSURE
- To measure the gas supply pressure use a
manometer with a minimum definition of 0,1
mbar.
- Remove the control panel.
- Remove the screw from on pressure test point PP
and connect the manometer to the test point.
- Make the measurement with the appliance in
operation.
IMPORTANT! IF THE GAS SUPPLY
PRESSURE IS NOT WITHIN THE LIMITS
(MIN. - MAX) INDICATED IN TABLE
TAB2, CEASE OPERATION OF THE
APPLIANCE AND CONTACT THE GAS
UTILITY COMPANY.
- Disconnect the manometer and retighten the
retaining screw on the pressure connection.
ELECTRIC EQUIPMENT
Switch on the appliance as directed in the
instructions and reminders for use given in Chapter
" INSTRUCTIONS FOR USE " and check:
- the current values of each phase.
- the correct operation of the heating elements.
III.

INSTRUCTIONS FOR USE

10. REMINDERS FOR THE USER

READ THIS MANUAL CAREFULLY. IT
PROVIDES IMPORTANT INFORMATION
FOR SAFE INSTALLATION, USE AND
MAINTENANCE OF THE APPLIANCE.
THE MANUFACTURER WILL NOT BE
LIABLE FOR ANY DAMAGE OR INJURY
RESULTING FROM FAILURE TO
OBSERVING THE FOLLOWING RULES.
For after-sales service, contact technical assistance
centres authorized by the manufacturer and
demand the use of original spare parts.
Have the appliance serviced at least twice a year.