6.5 Preparatory work before

installation

6.5.1 Attaching the bracket

Different types of supports are available (10
Accessories, page 54). Choose a suitable bracket for
the installation and follow all the instructions in the
suggested chapter.
Take special care when attaching and
fastening down the apparatus. If it is to be
attached to a concrete surface you must
use dowel pins with a traction torque rating
of at least 300dN each. For a metal surface
use screws with a diameter of at least 8mm
and of an appropriate length. The clamping
system must be able to support at least 4
times the weight of the entire equipment,
including P&T, lenses and camera.
The device should be assembled vertically.
Any other position could impair the
performance of the appliance.

6.5.2 Cables management

The connection cables should not be
accessible from the outside. It is necessary
to fasten the cables securely to the support
in order to prevent excessive weight pulling
them out accidentaly.
You must use cables suited to the type of
installation.
Insert the cables into the support so that they
protrude by about 50cm.
50cm
Fig. 7
MNVCUCZ_1511_EN
7 Installation
Never, under any circumstances, make
any changes or connections that are not
shown in this handbook. Failure to follow
the connection instructions that are given
in the handbook may create serious safety
hazards for people and for the installation.
Do not change the wiring in the product
as it is supplied to you. Failure to follow
this instruction may create serious safety
hazards for people and for the installation,
and will also invalidate the guarantee.
Keep a connection diagram for future
reference.
7.1 Connecting the cables to the
base
Insert the cables into the cable glands holding the
base at about 20cm from the support. Tighten the
cable glands. The cable glands are suitable for cables
with a diameter between 5mm and 10 mm.
Fig. 8
50cm
13