Scheppach HF50 Traduction Des Instructions D'origine page 25

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 26
The determination of the causes of these interference and their elimination always require heightened attention and caution.
Pull the mains plug!
In the following are some of the most common interferences and their causes listed. If you cannot correct faults and errors with
the machine, please contact your dealer.
Disturbance
Machine cannot be switched on
Machine switches off during the no-
load operation independently
Machine remains during working on
standstill
Number of revolutions drops during
the treatment
Careless milling picture
Splinter ejection clogs (without ex-
haust)
Troubleshooting
Probable cause
No mains voltage available.
Carbon brush conductors worn out.
Power failure
Response of the overload protection
because of blunt measurers or of too
large feed motion and/or thickness of
chip
Too large splinter acceptance
Too large feed motion
Milling cutter blunt
Milling cutter blunt
Uneven feed motion
Too large splinter acceptance
Milling cutter blunt
Too wet wood
Help
Control Voltage supply
Bring Machine into the service center
Control Net-lateral Pre-fuse
The machine does not restart by the
inserted under-voltage protection automati-
cally and must again be switched on after
tension return.
Before continuing with work exchange
measurers and/or wait for cooling of the
engine.
Reduce Splinter acceptance
Reduce Feed speed
Replace milling cutter
Replace milling cutter
Work with constant pressure and reduced
feed motion
Reduce Splinter acceptance
Exchange milling cutter
GB
25

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

49021059014902105924

Table des Matières