Having A Problem; Accessories - Chamberlain CD10 Instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

HAVING A PROBLEM?

Motor does not run
• Public electricity supply failure: Check with a
neighbor.
• Circuit breaker has tripped or fuse is blown: Check
house overload protector. If necessary, have an
authorized electrician redistribute the load.
• The switch is defective: Have it checked by an
authorized electrician and replaced if necessary.
• Repeated operation may have tripped the motor
overload protector switch: Wait 15 minutes and try
again.
Motor runs intermittently
• Have the wiring connection between switch and
motor checked by an authorized electrician. Replace
if necessary.
Motor does not shut off
• Check to be sure tube adapter is positioned all the
way up to the stop on the shaft.
• Check to be sure the motor has been inserted all the
way into the shaft.
Connection of the
11
Model 703280 switch
2I
PI
N
Main
L1.2 (brown)
230 V/50 Hz
N (blue)
PE (yellow-green)
Color Scale for Drive Table
1 yellow-green
Equipment Grounding Conductor PE
2 blue
Nuetral MP
3 black
Phase Direction of Rotation 1
4 brown
Phase Direction of Rotation 2
Connection of the
12
Model 703285 switch
L
L1.2 (brown)
Main
230 V/50 Hz
N (blue)
PE (yellow-green)
Color Scale for Drive Table
1 yellow-green
Equipment Grounding Conductor PE
2 blue
Nuetral MP
3 black
Phase Direction of Rotation 1
4 brown
Phase Direction of Rotation 2
1I
E
M
CD
L1.1 (black)
M
Control Cable
CD
4 x 0,75
M
CD
L1.1 (black)
M
Control Cable
CD
4 x 0,75
13
5
14:00
Rollotimer
10
14

ACCESSORIES

No
Item
(14.1) 704636
120785ASA
120758ASA
120756ASA
(14.2) TAO70ASA
400431
(14.3) TAP65ASA
(14.4) 120053
(14.5) 120995
(14.6) WTMZ1
(14.7) WTMT2
(14.8) 703280
(14.9) WTMLS1
(14.10) 121084
(14.11) TCS1ED
041A801417
708218
708223
041TM707008 Accessory pack CD20E4, CD30E4, CD50E4
Tubular Motor....................................................................................Model No. CD10, CD20E4
........................................................................................................................CD30E4, CD50E4
is in conformity to the applicable sections of Standards .....................EN55014, EN610003,
................................................................................ETS RES 0908, EN60555, & EN60335-1
per the provisions & all amendments of EU Directives .....................73/23/EEC, 89/336EEC
Tubular Motor Model CD10, CD20E4, CD30E4 and Model CD50E4, when installed and
maintained according to all the Manufacturer's instructions in combination with a shutter
which has also been installed and maintained according to all the Manufacturer's
instructions, meets the provisions of EU Directive 89/392EEC and all amendments.
I, the undersigned, hereby declare that the equipment specified above and any
accessory listed in the manual conforms to the above Directives and Standards.
Chamberlain GmbH
D-66793 Saarwellingen
Juli, 1998
11
2
3
4
8
7
11
Description
CD10
CD20E4
CD30E4
CD50E4
Tube adapter, octagonal 70mm
(Not for CD10)
Tube adapter, octagonal 40 mm
(Not for CD10)
Tube adapter, profile shaft 65 mm
(Not for CD10)
Octagonal tube 60mm (Not for CD10)
(list length when ordering)
End Cap for 120053
One central control module for each
connected motor
Timer
Wallswitch
Solar sensor for WTMT2
Universal wall bearing for 120053
Wall Switch
Programmable Timer
Accessory pack CD10 - Motor bracket
Accessory pack CD10 - Adapter
Declaration of Conformity
IDeclaration of Incorporation
Colin B. Willmott
1
6
9
Chief Engineer

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Cd20e4Cd30e4Cd50e4

Table des Matières