BEFORE OPERATION

Read section titled "SAFETY" (pages 4 – 8).
Make sure of the followings before operation.

WORKING ENVIRONMENT

● No fl ammable gas, liquid or other
fl ammable objects at worksite.
● Clear the area of children or
unauthorized personnel.

AIR SUPPLY

● NEVER use reactive
● Never connect Nailer to pressure
which potentially exceeds 200 psi
(13.7 bar 14 kgf/cm
fails.
● Never use non relieving coupler on
Nailer.
1. Power source
○ Use only clean, dry, regulated compressed
air as a power source for this Nailer.
○ Air
compressors
compressed air to this Nailer must comply
with the requirements of the latest version
of ANSI Standard B 19.3 "Safety Standard
For Compressors For Process Industries."
○ Moisture or oil in the air compressor may
accelerate wear and corrosion in the
Nailer.
Drain daily.
2. Filter-Regulator-Lubricator
○ Use a regulator with a pressure range of 0
– 120 psi (0 – 8.3 bar 0 – 8.5 kgf/cm
○ Filter-regulator-lubricator
an optimum condition for the Nailer and
extend the Nailer life. These units should
always be used.
WARNING
DANGER
gases or other bottled
gases. Explosion may
occur.
WARNING
) if a regulator
2
used
to
supply
).
2
units
supply
Filter:
The
fi lter
removes
dirt
mixed
Drain daily unless fi tted with an automatic
drain.
Keep
the
fi lter
maintenance.
Regulator:
The regulator controls the operating
pressure for safe operation of the Nailer.
Inspect the regulator before operation to
be sure it operates properly.
Lubricator:
The lubricator supplies an oil mist to the
Nailer.
Inspect the lubricator before operation to
be sure the supply of lubricant is adequate.
Use Hitachi pneumatic tool lubricant.
Nailer Side
Lubricator
3. Air hose
Compressed air supply hoses shall have
a minimum working pressure rating equal
to or greater than the pressure from the
power source if a regulator fails, or 150
psi (10.4 bar 10.6 kgf/cm
greater.
4. Air consumption
Using the Air consumption table and the
Air compressor size formula, fi nd a correct
compressor size.
Air consumption table
psi
Operating
(bar)
pressure
(kgf/cm
ft
/cycle
3
Air
consumption
(ltr/cycle) (1.07) (1.18) (1.29)
English
moisture
in
compressed
clean
by
regular
Regulator
Compressor
Side
Filter
), whichever is
2
80
90
100
(5.5)
(6.2)
(6.9)
) (5.6)
(6.3)
2
.038
.042
.045
and
air.
(7)
11

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Nt 65ma4s

Table des Matières