OPTIONAL ACCESSORIES

○ Pneumatic Tool Lubricant
.8 oz. (25 cc) oil feeder
4 oz. (120 cc) oil feeder
1 quart (1 ltr) can
NOTE: Accessories are subject to change without any
obligation on the part of HITACHI.

APPLICATIONS

○ Construction wooden work such as fl oor and wall
framing, roof decking, subfl ooring.
○ Mobile and modular home construction.
○ Making wooden boxes, palettes, and drums.
○ Packing operations in manufacturing plants, and
other types of packing and crating work in general.

BEFORE OPERATION

Read section titled "SAFETY" (pages 4 – 7).
Make sure of the followings before operation.

WORKING ENVIRONMENT

● No fl ammable gas, liquid or other fl ammable
objects at worksite.
● Clear the area of children or unauthorized
personnel.
AIR SUPPLY
● NEVER use oxygen or other
● Never
connect
which
potentially
(13.7 bar 14 kgf/cm
● Never use non relieving coupler on Nailer.
1. Power source
○ Use only clean, dry, regulated compressed air as a
power source for this Nailer.
10
... sold separately
(Code No. 877153)
(Code No. 874042)
(Code No. 876212)
WARNING
DANGER
bottled gases. Explosion may
occur.
WARNING
Nailer
to
pressure
exceeds
200
).
2
○ Air compressors used to supply compressed air to
this Nailer must comply with the requirements of
the latest version of ANSI Standard B 19.3 "Safety
Standard For Compressors For Process Industries."
○ Moisture or oil in the air compressor may accelerate
wear and corrosion in the Nailer.
Drain daily.
2. Filter-Regulator-Lubricator
○ Use a regulator with a pressure range of 0 – 120 psi
(0 – 8.3 bar 0 – 8.5 kgf/cm
○ Filter-regulator-lubricator units supply an optimum
condition for the Nailer and extend the Nailer life.
These units should always be used.
Filter ............ The fi lter removes moisture and dirt
mixed in compressed air.
Drain daily unless fi tted with an
automatic drain.
Keep the fi lter clean by regular
maintenance.
Regulator ......The regulator controls the operating
pressure for safe operation of the Nailer.
Inspect the regulator before operation to
be sure it operates properly.
Lubricator .... The lubricator supplies an oil mist to the
Nailer.
Inspect the lubricator before operation
to be sure the supply of lubricant is
adequate.
Use Hitachi pneumatic tool lubricant.
Nailer Side
3. Air hose
Air hose must have a minimum working pressure
rating of 150 psi (10.4 bar 10.6 kgf/cm
of the maximum pressure produced in the system,
psi
whichever is higher.
4. Air consumption
Using the Air consumption table and the Air
compressor size formula, fi nd a correct compressor
size.
).
2
Regulator
Compressor Side
Filter
Lubricator
) or 150%
2