10.4 Pythagoras
See drawing G:
Press key 8 three times.
The Pythagoras symbol appears on the
display.
Press key 4 and measure the first distance
(diagonal measurement).
Press key 4 and measure the second distance
(horizontal measurement).
The device displays the result in the summary
row and the respective measured distance to the
next measurement in the second row.
11 Troubleshooting
If the message Error does not disappear
after switching on the device repeatedly,
please contact the retailer.
If the message InFo appears with a number,
observe the instructions in the following
table.
No
Cause
.
204 Calculation error
252 Temperature too high
253 Temperature too low
255 Reception signal too
weak, measuring time
too long
256 Input signal too high
257 Measuring error, too
much background light
258 Measurement outside
of the measuring range
260 Laser beam interrupted Repeat the

12 Technical data

Range
Measuring accuracy (2 σ)
Smallest unit displayed
Laser class
Laser type
Automatic switch-off
Continuous measuring
Addition/Subtraction
Area
Volume
Pythagoras
Unit switching
Dimension (H x D x W)
Battery durability
(2 x AAA)
Weight
Temperature range:
- Storage
- Operation
* under favourable conditions (good target
surface, room temperature) up to 10 m. Under
unfavourable conditions such as bright sunlight,
Remedy
a very weakly reflecting target surface or large
temperature fluctuations, the deviation can rise
by ± 0.25 mm/m for distances over 10 m.
Perform measurement
12.1 Electromagnetic
again.
Let the device cool
down.
Warm the device up.
Change target surface
(e.g. white paper).
Possible disturbance of other devices
(e.g. safety equipment, medical equipment)
Change target surface
due to electromagnetic radiation!
(e.g. white paper).
Shadow the target
area.
Despite the compliance with all requirements of
Mind the range.
the corresponding directives and norms, a
disturbance of other devices is possible.

12.2 Laser classification

measurement.
The geo-Fennel EcoDist Plus generates a
visiblelaserbeam that is emotted on the front of
the device.
The device complies with laser class 2 according
0.1 m to 30 m
to:
Type.: ± 2.0 mm*
1 mm
2
635 nm, < 1 mW
after 180 s
yes
yes
yes
yes
yes
yes
118 x 50 x 26 mm
up to 3000
measurements
100 g
-25 °C to 70 °C
0 °C to 40 °C
compatibility (EMC)
Warning
Observe the safety instructions of the respective
devices.
IEC60825-1: 2007 Safety of laser products
EN60825-1: 2007 Safety of laser products