Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 60
INSULATION FROM THE EXTERNAL FEEDING SOURCES
Before to perform any operation of maintenance, cleaning and parts change, the external feeding sources must be sectioned
and insulated.
Position on "zero" the protection device placed upstream of the
electric equipment feeding line.
BREAKS OR DAMAGES RESEARCH AND MOVING ELEMENTS UNBLOCKING
Here follow are indicate the interventions for the breaks or damages research and moving elements unblocking which can
be performed from maintenance men.
TYPE
POTENTIAL CAUSE/S
General Black out
Net voltage
Fuses or magneto thermals intervention
lacking
place upstream of the machine feeding
line
Protection device intervention inside the
Functioning
machine
intervention
Cause/s not identifiable
Feeding voltage lacking.
Hopper not inserted or bad positioned
only on model TI 32R
The machine
Sectioning devices set on "OFF".
doesn't
function: the
Intervened fuses or not functioning
Archimedean
magneto thermals.
screw doesn't
rotate
Lacked running button functioning
Thermal intervention due to the
overheating

EXTRAORDINARY MAINTENANCE

For the intervention of extraordinary maintenance, consequent to breaks or revisions or mechanical and electric damages, it
is necessary an intervention request directly to the Authorized Assistance Center.
The instructions about the extraordinary maintenance don't appear in the present instruction manual for the use and so
must be explicitly requested to the manufacturer.
CLEANING
It is forbidden to clean by hand the organs and the elements in motion.
All cleaning interventions must be started only and exclusively, after having unloaded the machine with the
food product in working and having insulated from the electric feeding source and from external energy.
The machine, the electric equipment and the machine board components must not be ever washed utilizing
water, and not in any kind of jets form and quantity; so, without "bucket" nor "rubber" nor "towel". Don't
put ever directly the machine in the sink or under the tap.
The machine hygiene level classification and the associated equipment, for the foreseen use, is 2 (two): machine that, after
an hygiene risk evaluation, is in conformance with applicable international standards requirements, but requests a programmed
disassembly for the cleaning.
Disconnect the general sectioning device and provide to
protect the plug with proper systems
MODALITY AND COMPARISONS
Contact the electric energy distributor
After having eliminated the causes that have determined the protection device
intervention, restore it. In case of problem persistency contact an electrician
technician.
Contact an electrician technician: after having eliminated the causes that have
determined the protection device intervention, restore it.
In case of fuses intervention, change them with types of the same model,
calibration and intervention curve.
Contact directly the Authorized Assistance Center
Check and restore the electric energy.
Insert or reposition the hopper
Turn the sectioning devcies in the position "ON"
Change the intervened fuses, check the magneto thermal switches state.
Check the START button efficiency and eventually contact directly the Authorized
Assistance Center.
Wait the complete cooling before the machine restarting