Example 2: You wish to read out the present value of CV902 of the S.U.S.I. module:
3.
Enter 902-800=102 in the indicator CV126.
4.
Read out the transport device CV127. The value of CV902 of the connected module is
displayed.
4.12 USP – Uninterruptable Signal Processing
In combination with the optional energy storage, the intelligent USP circuit ensures that your
locomotive can run even over dirty track sections or dead frogs. The energy storage is not included
with this decoder and is installed separately in the vehicle.
Three terminal screws are provided on the decoder for the connection of the energy storage (e.g.
Power 1). See Fig. 3, p. 6.
4.13 Coupling control
The decoder allows for a comfortable controlling of remote couplings at all function outputs. The
selected output provides full power for a settable period of time (kick duration) and reduced power
after this period has expired. By how much the power is decreased can be set using the value for
brightness for the choosen output. You can also set if and how long the locomotive is to move
during the coupling process.
4.14 RailCom
The GOLD maxi is equipped with the RailCom function. In addition to the locomotive address, other
data (e.g. speed, CV content) can be transmitted from the locomotive via the track back to the
system. The information sent is received by a RailCom detector and then displayed. Which data
the decoder is to send is set in CV28. Set Bit 4 in CV29 to enable the transmission function.