10. Technical Specifications

10.1 CR200 GPRS Control Panel

Radio communication method .................................. FM
Frequency ................................................................ 868MHz
Radio range ............................................................. 200m
Power supply ........................................................... AC Adapter, 7.2V
Battery ..................................................................... 4.8V 600mAh
Batteries' life ............................................................ 10 hours (estimation)
Low battery indication .............................................. Yellow LED on + LCD fault display
Arm mode ................................................................ Global / Partial
Maximum number of inputs (zones) ......................... 30
Maximum number of radio sirens ............................. 30 (included in wireless zones)
Maximum number of remote controls ....................... 30
Maximum number of keyboard ................................. 30
Maximum number of recordable events ................... 20
Integrated alarm devices (buzzer) ............................ 95 dBA
Protections ............................................................... Anti-jamming, anti-removal, anti-opening
Working temperature ............................................... -10°C ÷ +45°C
Case material ........................................................... ABS707
Dimensions (l x h x w) .............................................. 209 x 136 x 34,2 mm

10.2 RC200 Remote Controller

Radio communication method .................................. FM
Frequency ................................................................ 868MHz
Radio range ............................................................. 100m
Batteries .................................................................. 230mAh lithium CR2032 battery
Batteries' life ............................................................ 2 years
Low battery indication .............................................. Signal to the control panel, panel will display
the status
Controls (buttons) .................................................... Arm/ Disarm/ Partial arm (home mode)/ Panic
Signalling ................................................................. Red LED
Working temperature ............................................... -10°C ÷ +45°C
Case material ........................................................... ABS707
Dimensions (l x h x w) .............................................. 65x38x15mm

10.3 SD200 Smoke Detector

Radio communication method .................................. FM
Frequency ................................................................ 868MHz
Radio range ............................................................. 200m
Integral buzzer sound pressure ................................ 95dB @ 1m
Batteries .................................................................. 4x AAA Alkaline
Batteries' life ............................................................ 2 years
Working temperature ............................................... -10°C ÷ +45°C
Relative humidity...................................................... > 95%
Supervision interval .................................................. 30-50 min.
Case material ........................................................... ABS765A
Dimensions (Ø x h) .................................................. 105x42mm